Carrier / AIR-SOURCE HEAT PUMP

27VNA060A*030*

Infinity 20 VS Heat Pump · source records, page 8

158 published source records · source checked Sep 21, 2026

SEER2 range16.5–19BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for 27VNA060A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 158 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.5–19158 / 158
EER2 · BTU/Wh8–9.8158 / 158
HSPF2 · BTU/Wh8.1–9158 / 158
Cooling capacity · BTU/h54,000–58,000158 / 158
Heating capacity at 47°F / 8.3°C · BTU/h59,000–63,50054 / 158
Heating capacity at 17°F / −8.3°C · BTU/h50,500–57,500158 / 158
Heating capacity at 5°F / −15°C · BTU/h41,000–46,000158 / 158
COP at 5°F / −15°C1.86–2.1158 / 158
Equipment / loop typeHP - Split System158 / 158
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)158 / 158
Compressor stagingContinuously variable158 / 158
Connected capabilityNo158 / 158

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA6021XMA*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567704317.508.50460001.94EPA 3971528
CVAVA6021XMA*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567739317.508.50460001.94EPA 3971843
CVAVA6121XMA*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567761317.509.00460002.06EPA 3972064
CVAVA6024XMA*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567750317.508.50455001.94EPA 3972158
CAA**6024AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567782317.508.50425001.86EPA 3972637
CAA**6124AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567797317.508.50430001.88EPA 3973311
CSAH*6012AM*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 21567803317.008.50415001.90EPA 3973369
CSAH*6012AM*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 21567804317.008.50420001.90EPA 3973385
CSAH*6012AM*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 21567809317.008.50415001.90EPA 3973399
CSAH*6012AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21567813317.008.50420001.90EPA 3973429
CSAH*6012AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21567814317.008.50420001.90EPA 3973443
CSAH*6012AM*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 21567815317.008.50420001.90EPA 3973455
CSAH*6012AM*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 21567816317.008.50420001.90EPA 3973460
CSAH*6012AM*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 21568271317.008.50420001.90EPA 3978047
CSAH*6012AM*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 21568276317.008.50420001.90EPA 3978074
CSAH*6012AM*+UI+ furnace: 59TN7A100C21**22Cold climate designationAHRI reference: 21568277317.008.50420001.90EPA 3978076
CSAH*6012AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 21567810316.508.50420001.90EPA 3973410
CSAH*6012AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21567812316.508.10425001.88EPA 3973421

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →