Heating performance & equipment details
Ranges include the 158 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 158 / 158 |
| EER2 · BTU/Wh | 8–9.8 | 158 / 158 |
| HSPF2 · BTU/Wh | 8.1–9 | 158 / 158 |
| Cooling capacity · BTU/h | 54,000–58,000 | 158 / 158 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–63,500 | 54 / 158 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 158 / 158 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 158 / 158 |
| COP at 5°F / −15°C | 1.86–2.1 | 158 / 158 |
| Equipment / loop type | HP - Split System | 158 / 158 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 158 / 158 |
| Compressor staging | Continuously variable | 158 / 158 |
| Connected capability | No | 158 / 158 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA6024XMA*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 215677533 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3972187 → |
CVAVA6024XMA*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215677543 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3972196 → |
CVAVA6024XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 215677553 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3972209 → |
CVAVA6124XMA*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 215677643 | 18.50 | 9.00 | 44500 | 2.10 | EPA 3972291 → |
CVAVA6124XMA*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 215677693 | 18.50 | 9.00 | 45000 | 2.06 | EPA 3972427 → |
CVAVA6124XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215677703 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3972434 → |
CVAVA6124XMA*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215677723 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3972457 → |
CVAVA6124XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 215677733 | 18.50 | 9.00 | 44500 | 2.10 | EPA 3972473 → |
CAA**6024AM*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 215677743 | 18.50 | 8.50 | 41500 | 2.02 | EPA 3972482 → |
CAA**6024AM*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215677773 | 18.50 | 9.00 | 41500 | 2.04 | EPA 3972591 → |
CAA**6024AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215677843 | 18.50 | 8.50 | 41500 | 1.90 | EPA 3972596 → |
CAA**6024AM*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215677783 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3972602 → |
CAA**6024AM*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215677793 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3972606 → |
CAA**6024AM*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215677813 | 18.50 | 8.50 | 41500 | 2.04 | EPA 3972634 → |
CAA**6024AM*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 215677853 | 18.50 | 8.50 | 41500 | 1.90 | EPA 3972672 → |
CAA**6024AM*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215677863 | 18.50 | 8.50 | 41500 | 1.90 | EPA 3972687 → |
CAA**6024AM*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 215677873 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3972714 → |
CAA**6124AM*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 215677893 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3972985 → |
CAA**6124AM*+UI+ furnace: 58TN*B070C21**20Cold climate designationAHRI reference: 215677913 | 18.50 | 9.00 | 42000 | 2.00 | EPA 3972998 → |
CAA**6124AM*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215677963 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3973301 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.