Carrier / AIR-SOURCE HEAT PUMP

27VNA048A*030*

Infinity 20 VS Heat Pump

376 published source records · source checked Sep 21, 2026

SEER2 range15.5–19.5BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity43,500–49,000BTU/h

Each efficiency range summarizes published EPA records for 27VNA048A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–19.5376 / 376
EER2 · BTU/Wh9–10.5376 / 376
HSPF2 · BTU/Wh8.5–9.5376 / 376
Cooling capacity · BTU/h43,500–49,000376 / 376
Heating capacity at 47°F / 8.3°C · BTU/h47,000–50,000376 / 376
Heating capacity at 17°F / −8.3°C · BTU/h41,000–47,500376 / 376
Heating capacity at 5°F / −15°C · BTU/h33,000–37,600376 / 376
COP at 5°F / −15°C1.92–2.2376 / 376
Equipment / loop typeHP - Split System376 / 376
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)376 / 376
Compressor stagingContinuously variable376 / 376
Connected capabilityNo376 / 376

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FE5BNBD60L*+UICold climate designationAHRI reference: 21567534319.509.50330002.20EPA 3969019
CVAMA6124XMA*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 21567595319.509.00366002.10EPA 3969468
CVAMA6124XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 21567598319.509.50366002.10EPA 3969492
CVAMA6124XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 21567599319.509.50366002.10EPA 3969505
CVAMA6124XMA*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 21567600319.509.50366002.10EPA 3969514
CVAMA6124XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21567605319.509.50366002.12EPA 3970002
CVAMA6124XMA*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 21567606319.509.50368002.12EPA 3970012
CVAMA6124XMA*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 21567607319.509.50366002.12EPA 3970027
CVAMA6124XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 21567608319.509.50366002.12EPA 3970042
CVAVA6121XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 21567674319.509.50366002.12EPA 3970412
CVAVA6121XMA*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 21567675319.509.50366002.12EPA 3970423
CVAVA6121XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21567681319.509.50368002.12EPA 3970563
CVAVA6121XMA*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 21567683319.509.50368002.12EPA 3970590
CVAVA6124XMA*+UI+ furnace: 58CU*A080C21**20Cold climate designationAHRI reference: 21567684319.509.00366002.10EPA 3970601
CVAVA6124XMA*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 21567687319.509.50366002.10EPA 3970794
CVAVA6124XMA*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 21567688319.509.50366002.10EPA 3970797
CVAVA6124XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21567692319.509.50368002.12EPA 3971337
CVAVA6124XMA*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 21567693319.509.50368002.12EPA 3971344
CVAVA6124XMA*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 21567694319.509.50368002.12EPA 3971355
CVAVA6124XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 21567695319.509.50366002.12EPA 3971361

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →