Carrier / AIR-SOURCE HEAT PUMP

27VNA036A*030*

Infinity 20 VS Heat Pump · source records, page 8

300 published source records · source checked Sep 21, 2026

SEER2 range16–19.5BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity32,600–35,400BTU/h

Each efficiency range summarizes published EPA records for 27VNA036A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 300 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19.5300 / 300
EER2 · BTU/Wh9–11.5300 / 300
HSPF2 · BTU/Wh8.5–9.5300 / 300
Cooling capacity · BTU/h32,600–35,400300 / 300
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200300 / 300
Heating capacity at 17°F / −8.3°C · BTU/h29,400–31,400300 / 300
Heating capacity at 5°F / −15°C · BTU/h24,400–26,000300 / 300
COP at 5°F / −15°C1.75–2.04300 / 300
Equipment / loop typeHP - Split System300 / 300
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)300 / 300
Compressor stagingContinuously variable300 / 300
Connected capabilityNo300 / 300

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**4321AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 21568398917.509.00252001.88EPA 3717907
CAA**4321AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 21568399517.509.00254001.88EPA 3717910
CAA**3717AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 21568387717.509.00254001.88EPA 3717918
CAA**3721AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 21568391917.509.00254001.88EPA 3717919
CAA**6121AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 21566950217.509.00250001.90EPA 3717924
CAA**3721AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21567929317.509.00250001.90EPA 3717925
CAA**4221AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 21567935317.508.50256001.86EPA 3717927
CAA**4221AM*+UI+ furnace: 59TN7A080C21**20Cold climate designationAHRI reference: 21567939317.509.00256001.86EPA 3717928
CAA**4321AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 21568399117.509.00252001.88EPA 3717953
CAA**3717AM*+UI+ furnace: 58CU*A060C17**16Cold climate designationAHRI reference: 21568386917.509.00256001.88EPA 3717976
CAA**3721AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21568391717.509.00254001.88EPA 3717978
CAA**3721AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 21568392517.509.00254001.88EPA 3717979
CAA**4221AM*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 21568395317.509.00256001.84EPA 3717980
CAA**3717AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 21568388717.509.00256001.86EPA 3718003
CAA**4221AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21568396117.509.00256001.86EPA 3718009
CAA**4821AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 21566921217.509.00254001.88EPA 3718013
CAA**3721AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21567931317.509.00254001.88EPA 3718034
CAA**4221AM*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 21567934317.509.00256001.86EPA 3718035
CAA**4221AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21567936317.508.50256001.84EPA 3718110
CAA**3717AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 21568388917.509.00256001.88EPA 3718193

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →