27VNA036A*030*
Infinity 20 VS Heat Pump
300 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA036A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 300 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19.5 | 300 / 300 |
| EER2 · BTU/Wh | 9–11.5 | 300 / 300 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 300 / 300 |
| Cooling capacity · BTU/h | 32,600–35,400 | 300 / 300 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 300 / 300 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–31,400 | 300 / 300 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,400–26,000 | 300 / 300 |
| COP at 5°F / −15°C | 1.75–2.04 | 300 / 300 |
| Equipment / loop type | HP - Split System | 300 / 300 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 300 / 300 |
| Compressor staging | Continuously variable | 300 / 300 |
| Connected capability | No | 300 / 300 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FE5BNBD60L*+UICold climate designationAHRI reference: 215670616 | 19.50 | 9.50 | 24400 | 2.04 | EPA 3719291 → |
FE5BN(B,X)C48L*+UICold climate designationAHRI reference: 215662626 | 19.00 | 9.00 | 24600 | 1.96 | EPA 3717843 → |
CAA**6124AM*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 215669732 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717673 → |
CAA**6121AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215669572 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717687 → |
CAA**6121AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 215669482 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717711 → |
CAA**6124AM*+UI+ furnace: 59TN7A100C21**22Cold climate designationAHRI reference: 215679683 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717721 → |
CAA**6121AM*+UI+ furnace: 59TN7A100C21**22Cold climate designationAHRI reference: 215679653 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717725 → |
CAA**6024AM*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215669322 | 18.50 | 9.00 | 24600 | 1.92 | EPA 3717774 → |
CAA**6024AM*+UI+ furnace: 59MN7C120C24**22Cold climate designationAHRI reference: 215669392 | 18.50 | 9.00 | 24800 | 1.90 | EPA 3717785 → |
CAA**6124AM*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215669722 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717787 → |
CAA**6024AM*+UI+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 215679583 | 18.50 | 9.00 | 24800 | 1.90 | EPA 3717791 → |
CAA**6024AM*+UI+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 215669312 | 18.50 | 9.00 | 24600 | 1.92 | EPA 3717819 → |
CAA**6121AM*+UI+ furnace: 59TN6C100C21**22Cold climate designationAHRI reference: 215669602 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717820 → |
CAA**6124AM*+UI+ furnace: 58TN*B070C21**20Cold climate designationAHRI reference: 215669622 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717846 → |
CAA**6124AM*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215669652 | 18.50 | 9.00 | 24600 | 1.92 | EPA 3717847 → |
CAA**6124AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 215669702 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717880 → |
CAA**6124AM*+UI+ furnace: 59CU5B100C21**22Cold climate designationAHRI reference: 215669672 | 18.50 | 9.00 | 24600 | 1.92 | EPA 3717881 → |
CAA**6121AM*+UI+ furnace: 58TN*B110C21**20Cold climate designationAHRI reference: 215669492 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717886 → |
CAA**6024AM*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 215669332 | 18.50 | 9.00 | 24600 | 1.92 | EPA 3717888 → |
CAA**6124AM*+UI+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 215679693 | 18.50 | 9.00 | 24800 | 1.92 | EPA 3717915 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →