27VNA024A*030*
Infinity 20 VS Heat Pump · source records, page 3
104 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA024A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 104 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18 | 104 / 104 |
| EER2 · BTU/Wh | 9–10.5 | 104 / 104 |
| HSPF2 · BTU/Wh | 8.5–9 | 104 / 104 |
| Cooling capacity · BTU/h | 22,400–24,200 | 104 / 104 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,200–24,600 | 104 / 104 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,600–20,800 | 104 / 104 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,300–17,300 | 104 / 104 |
| COP at 5°F / −15°C | 1.82–2.02 | 104 / 104 |
| Equipment / loop type | HP - Split System | 104 / 104 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 104 / 104 |
| Compressor staging | Continuously variable | 104 / 104 |
| Connected capability | No | 104 / 104 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**2517AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 215678223 | 17.00 | 9.00 | 16300 | 2.02 | EPA 3800164 → |
CAA**2517AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 215678233 | 17.00 | 9.00 | 16300 | 2.02 | EPA 3800174 → |
CAA**2517AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 215683599 | 17.00 | 9.00 | 16500 | 2.00 | EPA 3800197 → |
CAA**3617AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 215683663 | 17.00 | 9.00 | 16600 | 1.98 | EPA 3800231 → |
CAA**3717AM*+UI+ furnace: 58CU*A040C17**12Cold climate designationAHRI reference: 215683665 | 17.00 | 9.00 | 16500 | 2.00 | EPA 3800241 → |
CAA**3617AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 215683661 | 17.00 | 9.00 | 16700 | 1.96 | EPA 3801258 → |
CAA**3617AM*+UI+ furnace: 58CU*A040C17**12Cold climate designationAHRI reference: 215683643 | 17.00 | 9.00 | 16600 | 1.98 | EPA 3801267 → |
CAA**3617AM*+UI+ furnace: 58CU*A060C17**16Cold climate designationAHRI reference: 215683645 | 17.00 | 9.00 | 16600 | 1.98 | EPA 3801278 → |
CAA**3717AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 215683669 | 17.00 | 9.00 | 16600 | 1.98 | EPA 3801280 → |
CAA**2517AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 215678253 | 17.00 | 9.00 | 16500 | 2.02 | EPA 3801296 → |
CAA**3017AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 215678263 | 17.00 | 8.50 | 16600 | 1.98 | EPA 3801306 → |
CAA**2517AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 215683607 | 17.00 | 9.00 | 16500 | 2.00 | EPA 3801323 → |
CAA**3717AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 215683685 | 17.00 | 9.00 | 16500 | 2.00 | EPA 3801329 → |
CAA**3617AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 215678333 | 17.00 | 9.00 | 16700 | 1.98 | EPA 3801359 → |
CAA**3014AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 215683617 | 17.00 | 8.50 | 16700 | 1.86 | EPA 3801361 → |
CAA**3617AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 215683655 | 17.00 | 9.00 | 16700 | 1.98 | EPA 3801364 → |
CAA**3617AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 215683657 | 17.00 | 9.00 | 16700 | 1.98 | EPA 3801375 → |
CAA**3721AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 215678403 | 17.00 | 9.00 | 16400 | 2.02 | EPA 3801397 → |
CAA**3717AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 215678343 | 17.00 | 9.00 | 16400 | 2.00 | EPA 3801410 → |
CAA**3717AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 215678373 | 17.00 | 9.00 | 16500 | 2.00 | EPA 3801436 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.