Carrier / AIR-SOURCE HEAT PUMP

27TPA848A**30*

2-STAGE 18 SEER HP · source records, page 9

432 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 27TPA848A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 432 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18432 / 432
EER2 · BTU/Wh11.7–13.5432 / 432
HSPF2 · BTU/Wh7.8–8.5432 / 432
Cooling capacity · BTU/h45,500–50,500432 / 432
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500432 / 432
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600432 / 432
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600432 / 432
COP at 5°F / −15°C2.06–2.32432 / 432
Equipment / loop typeHP - Split System432 / 432
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)432 / 432
Compressor stagingTwo-stage432 / 432
Connected capabilityNo432 / 432

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA4821XMA*+ furnace: 59MN7C100C21**22AHRI reference: 21562427516.508.10244002.12EPA 3948226
CVAVA4821XMA*+ furnace: 59SP6B100V21**20AHRI reference: 21562430216.508.10244002.12EPA 3948253
CVAMA6021XMA*+ furnace: 58TN*B070C21**20AHRI reference: 21562374416.508.10256002.08EPA 3948306
CVAMA6021XMA*+ furnace: 59CU5B080C21**20AHRI reference: 21562382016.508.10252002.10EPA 3948381
CVAVA4821XMA*+ furnace: 59SU5B100M21**20AHRI reference: 21562431516.508.10244002.12EPA 3948409
CVAVA4821XMA*+ furnace: 59SU5B100M21**22AHRI reference: 21562433416.508.10242002.16EPA 3948431
CVAVA4821XMA*+ furnace: 59TN6C100C21**22AHRI reference: 21562436216.508.10244002.12EPA 3948458
CVAMA6021XMA*+ furnace: 59MN7C080C21**20AHRI reference: 21562386216.508.10252002.08EPA 3948472
CVAMA6021XMA*+ furnace: 59SP6B080V21**20AHRI reference: 21562389016.508.10248002.12EPA 3948503
CVAMA6021XMA*+ furnace: 59SP6B100V21**20AHRI reference: 21562390316.508.10248002.12EPA 3948516
CVAMA6021XMA*+ furnace: 59SU5B080M21**20AHRI reference: 21562391616.508.10250002.12EPA 3948528
CVAMA6021XMA*+ furnace: 59TP6C080V21**20AHRI reference: 21562399616.508.10248002.12EPA 3948608
CVAVA4821XMA*+ furnace: 59TP6C100V21**20AHRI reference: 21562439216.508.10244002.12EPA 3948632
CVAVA4821XMA*+ furnace: GG96VTAB60100C**AHRI reference: 21562439316.508.10244002.12EPA 3948634
CVAVA4924XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562448316.508.10250002.12EPA 3948724
CVAVA4924XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562451316.508.10248002.12EPA 3948755
CVAVA4924XMA*+ furnace: 59CU5B080C21**20AHRI reference: 21562453916.508.10254002.08EPA 3948779
CVAVA4924XMA*+ furnace: 59SP6B080V21**20AHRI reference: 21562456716.508.10254002.10EPA 3948790
CVAVA4924XMA*+ furnace: 59SP6B100V21**20AHRI reference: 21562458016.508.10252002.12EPA 3948805
CVAVA4924XMA*+ furnace: 59SP6B120V24**22AHRI reference: 21562459316.508.10252002.10EPA 3948820