Carrier / AIR-SOURCE HEAT PUMP

27TPA848A**30*

2-STAGE 18 SEER HP · source records, page 5

432 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 27TPA848A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 432 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18432 / 432
EER2 · BTU/Wh11.7–13.5432 / 432
HSPF2 · BTU/Wh7.8–8.5432 / 432
Cooling capacity · BTU/h45,500–50,500432 / 432
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500432 / 432
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600432 / 432
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600432 / 432
COP at 5°F / −15°C2.06–2.32432 / 432
Equipment / loop typeHP - Split System432 / 432
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)432 / 432
Compressor stagingTwo-stage432 / 432
Connected capabilityNo432 / 432

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6121XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562513517.008.50248002.14EPA 3949349
CVAVA6124XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562541917.008.50250002.26EPA 3949365
CVAVA6124XMA*+ furnace: 59SP6B120V24**22AHRI reference: 21562560417.008.50252002.24EPA 3949378
CVAVA6124XMA*+ furnace: 59SU5B100M21**20AHRI reference: 21562563617.008.10252002.12EPA 3949410
CVAVA6121XMA*+ furnace: 59SP6B100V21**20AHRI reference: 21562523817.008.10250002.12EPA 3949490
CVAVA6121XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562516917.008.10246002.14EPA 3949494
CVAVA6121XMA*+ furnace: 59MN7C080C21**20AHRI reference: 21562519717.008.10252002.10EPA 3949510
CVAVA6121XMA*+ furnace: 59MN7C100C21**22AHRI reference: 21562521117.008.10254002.10EPA 3949531
CVAVA6121XMA*+ furnace: 59SP6B080V21**20AHRI reference: 21562522517.008.10250002.10EPA 3949543
CVAVA6121XMA*+ furnace: 59SU5B100M21**20AHRI reference: 21562527017.008.50248002.12EPA 3949567
CVAVA6121XMA*+ furnace: 59TN6C080C21**20AHRI reference: 21562530317.008.50252002.10EPA 3949603
CVAVA6121XMA*+ furnace: 59TN6C100C21**22AHRI reference: 21562531717.008.10254002.10EPA 3949616
CVAVA6121XMA*+ furnace: 59TP6C080V21**20AHRI reference: 21562533117.008.10250002.10EPA 3949630
CVAVA6124XMA*+ furnace: 59MN7C100C21**22AHRI reference: 21562555017.008.10252002.12EPA 3949655
CVAVA6124XMA*+ furnace: 59SP6B080V21**20AHRI reference: 21562557817.008.10256002.10EPA 3949683
CVAVA6124XMA*+ furnace: 59SP6B100V21**20AHRI reference: 21562559117.008.10254002.10EPA 3949696
CVAVA6121XMA*+ furnace: 59TP6C100V21**20AHRI reference: 21562534717.008.10250002.12EPA 3949718
CVAVA6121XMA*+ furnace: GG96VTAB60100C**AHRI reference: 21562534817.008.10250002.12EPA 3949719
CVAVA6124XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562538017.008.50250002.26EPA 3949748
CVAVA6124XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562545217.008.50250002.26EPA 3949787