Carrier / AIR-SOURCE HEAT PUMP

27TPA848A**30*

2-STAGE 18 SEER HP · source records, page 18

432 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 27TPA848A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 432 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18432 / 432
EER2 · BTU/Wh11.7–13.5432 / 432
HSPF2 · BTU/Wh7.8–8.5432 / 432
Cooling capacity · BTU/h45,500–50,500432 / 432
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500432 / 432
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600432 / 432
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600432 / 432
COP at 5°F / −15°C2.06–2.32432 / 432
Equipment / loop typeHP - Split System432 / 432
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)432 / 432
Compressor stagingTwo-stage432 / 432
Connected capabilityNo432 / 432

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*6012AM*+ furnace: 58SP*B135V24**22AHRI reference: 21563407516.008.00250002.25EPA 3953997
CSAH*6012AM*+ furnace: 58SU*B060M17**16AHRI reference: 21563408816.007.80252002.20EPA 3954008
CSAH*6012AM*+ furnace: 58SU*B080M21**20AHRI reference: 21563410716.008.00248002.25EPA 3954027
CSAH*6012AM*+ furnace: GG96VTAB60100C**AHRI reference: 21563463416.008.00252002.25EPA 3954034
CSAH*6012AM*+ furnace: 59TP6C100V21**20AHRI reference: 21563463316.008.00252002.25EPA 3954035
CSAH*6012AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563465316.008.00250002.25EPA 3954058
CSAH*6012AM*+ furnace: 59TP6C120V24**22AHRI reference: 21563466616.008.00252002.25EPA 3954066
CSAH*6012AM*+ furnace: GG96VTAB66120D**AHRI reference: 21563466716.008.00252002.25EPA 3954072
CSAH*6012AM*+ furnace: 58TN*B070C21**20AHRI reference: 21563417316.008.00254002.20EPA 3954131
CSAH*6012AM*+ furnace: 58TN*B090C21**20AHRI reference: 21563418716.008.00252002.25EPA 3954149
CSAH*6012AM*+ furnace: 58TN*B110C21**20AHRI reference: 21563420116.008.00252002.25EPA 3954160
CSAH*6012AM*+ furnace: 58TN*B135C24**22AHRI reference: 21563421516.008.00250002.25EPA 3954174
CSAH*6012AM*+ furnace: 58TP*B090V21**20AHRI reference: 21563424516.008.00250002.25EPA 3954189
CSAH*6012AM*+ furnace: 58TP*B110V21**22AHRI reference: 21563426116.008.00250002.25EPA 3954204
CSAH*6012AM*+ furnace: 58TP*B135V24**22AHRI reference: 21563427916.008.00250002.25EPA 3954224
CSAH*6012AM*+ furnace: 59MN7C120C24**22AHRI reference: 21563438516.008.00254002.20EPA 3954246
CSAH*6012AM*+ furnace: 59SP6B080V21**20AHRI reference: 21563442516.008.00252002.20EPA 3954261
CSAH*6012AM*+ furnace: 59SP6B100V21**20AHRI reference: 21563443816.008.00252002.20EPA 3954275
CSAH*6012AM*+ furnace: 59SP6B120V24**22AHRI reference: 21563445116.008.00252002.25EPA 3954284
CAA**6024AM*+ furnace: 59TP7A100V21**22AHRI reference: 21572175616.008.00254002.22EPA 3981808

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →