Carrier / AIR-SOURCE HEAT PUMP

27TPA848A**30*

2-STAGE 18 SEER HP · source records, page 12

432 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for 27TPA848A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 432 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18432 / 432
EER2 · BTU/Wh11.7–13.5432 / 432
HSPF2 · BTU/Wh7.8–8.5432 / 432
Cooling capacity · BTU/h45,500–50,500432 / 432
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500432 / 432
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600432 / 432
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600432 / 432
COP at 5°F / −15°C2.06–2.32432 / 432
Equipment / loop typeHP - Split System432 / 432
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)432 / 432
Compressor stagingTwo-stage432 / 432
Connected capabilityNo432 / 432

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6121AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563269716.508.10256002.22EPA 3953211
CAA**6124AM*+ furnace: 58SU*B080M21**20AHRI reference: 21563282816.508.10256002.20EPA 3953384
CVAMA6021XMA*+ furnace: 59TP7A080V21**20AHRI reference: 21572205716.508.00248002.12EPA 3981696
CVAMA6021XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21572207316.508.00246002.14EPA 3981713
CVAVA4821XMA*+ furnace: 58CU*B080C21**20AHRI reference: 21572210416.508.00240002.14EPA 3981741
CVAVA4821XMA*+ furnace: 59TN7A100C21**22AHRI reference: 21572211816.508.10244002.15EPA 3981757
CVAVA4821XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21572213216.508.00244002.12EPA 3981778
CVAVA4924XMA*+ furnace: 59TN7A120C24**22AHRI reference: 21572216316.508.00252002.10EPA 3981879
CVAVA6021XMA*+ furnace: 58CU*B040C17**12AHRI reference: 21572219016.508.00246002.14EPA 3981899
CVAVA6021XMA*+ furnace: 58CU*B100C21**20AHRI reference: 21572221816.508.00246002.14EPA 3981925
CAA**6121AM*+ furnace: 59TP7A100V21**22AHRI reference: 21572183116.508.00252002.24EPA 3982245
CVAMA4821XMA*+ furnace: 58CU*B080C21**20AHRI reference: 21572187116.508.00242002.14EPA 3982291
CVAMA4821XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21572188516.508.00242002.12EPA 3982298
CVAMA4921XMA*+ furnace: 59TN7A080C21**20AHRI reference: 21572191216.508.00252002.10EPA 3982325
CVAMA4921XMA*+ furnace: 59TP7A080V21**20AHRI reference: 21572194016.508.00250002.12EPA 3982354
CVAMA4921XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21572195616.508.00250002.10EPA 3982373
CVAMA6021XMA*+ furnace: 58CU*B040C17**12AHRI reference: 21572198716.508.00246002.14EPA 3982400
CVAMA6021XMA*+ furnace: 59TN7A080C21**20AHRI reference: 21572202916.508.00252002.10EPA 3982439
CVAVA6021XMA*+ furnace: 59TP7A080V21**20AHRI reference: 21572226016.508.00248002.12EPA 3982468
CVAVA6021XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21572227616.508.00246002.14EPA 3982485

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →