Carrier / AIR-SOURCE HEAT PUMP

27TPA836A**30*

2-STAGE 18 SEER HP · source records, page 8

285 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA836A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17285 / 285
EER2 · BTU/Wh11.7–13285 / 285
HSPF2 · BTU/Wh7.8–8.5285 / 285
Cooling capacity · BTU/h33,800–38,000285 / 285
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000285 / 285
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200285 / 285
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600285 / 285
COP at 5°F / −15°C1.78–2.48285 / 285
Equipment / loop typeHP - Split System285 / 285
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)285 / 285
Compressor stagingTwo-stage285 / 285
Connected capabilityNo285 / 285

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**4821AM*+ furnace: 58TP*B090V21**20AHRI reference: 21563909715.508.10192002.26EPA 3956252
CAA**4821AM*+ furnace: 58TP*B110V21**22AHRI reference: 21563912115.508.10191002.26EPA 3956269
CAA**4821AM*+ furnace: 59CU5B100C21**22AHRI reference: 21563919515.508.10190002.26EPA 3956301
CAA**4821AM*+ furnace: 59MN7C080C21**20AHRI reference: 21563928015.508.10191002.26EPA 3956315
CAA**4821AM*+ furnace: 59MN7C100C21**22AHRI reference: 21563930915.508.10191002.26EPA 3956329
CAA**4821AM*+ furnace: 59SP6B100V21**20AHRI reference: 21563939115.508.10193002.24EPA 3956357
CAA**4821AM*+ furnace: GG96VTAB60100C**AHRI reference: 21563971715.508.10191002.26EPA 3956421
CAA**4821AM*+ furnace: 59TP6C100V21**20AHRI reference: 21563971615.508.10191002.26EPA 3956422
CAA**4821AM*+ furnace: 59SU5B100M21**20AHRI reference: 21563949515.508.10191002.26EPA 3956461
CAA**4821AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563952415.508.10190002.26EPA 3956478
CAA**4821AM*+ furnace: 59TN6C100C21**22AHRI reference: 21563961015.508.10191002.26EPA 3956495
CSAH*4212AM*+ furnace: 58SU*B080M21**20AHRI reference: 21564100615.508.10190002.26EPA 3956728
CAA**3721AM*+ furnace: 59TN7A100C21**22AHRI reference: 21572137015.508.00193002.24EPA 3982095
CAA**3721AM*+ furnace: 59TP7A100V21**20AHRI reference: 21572138415.508.00193002.26EPA 3982111
CAA**4321AM*+ furnace: 59TN7A080C21**20AHRI reference: 21572153115.508.00193002.26EPA 3982134
CAA**4321AM*+ furnace: 59TN7A100C21**22AHRI reference: 21572154515.508.00193002.24EPA 3982156
CAA**4321AM*+ furnace: 59TP7A100V21**20AHRI reference: 21572155915.508.00192002.26EPA 3982169
CAA**4821AM*+ furnace: 59TN7A100C21**22AHRI reference: 21572157715.508.00191002.26EPA 3982188
CAA**4321AM*+ furnace: 59TP7A100V21**22AHRI reference: 21571505915.508.50192002.40EPA 3997684
F55AA*B36L*AHRI reference: 21646427015.208.10188002.28EPA 3847182

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →