Carrier / AIR-SOURCE HEAT PUMP

27TPA836A**30*

2-STAGE 18 SEER HP · source records, page 14

285 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA836A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17285 / 285
EER2 · BTU/Wh11.7–13285 / 285
HSPF2 · BTU/Wh7.8–8.5285 / 285
Cooling capacity · BTU/h33,800–38,000285 / 285
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000285 / 285
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200285 / 285
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600285 / 285
COP at 5°F / −15°C1.78–2.48285 / 285
Equipment / loop typeHP - Split System285 / 285
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)285 / 285
Compressor stagingTwo-stage285 / 285
Connected capabilityNo285 / 285

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*4812AM*+ furnace: 59MN7C100C21**22AHRI reference: 21564254615.208.10191002.26EPA 3956637 →
CSAH*4812AM*+ furnace: 59SP6B120V24**22AHRI reference: 21564263715.207.80190002.26EPA 3956655 →
CSAH*4812AM*+ furnace: 59SU5B080M21**20AHRI reference: 21564268815.207.80192002.26EPA 3956660 →
CSAH*4812AM*+ furnace: 59SU5B100M21**22AHRI reference: 21564274415.208.10190002.26EPA 3956683 →
CSAH*4812AM*+ furnace: 59TN6C100C21**22AHRI reference: 21564280615.208.10191002.26EPA 3956691 →
CSAH*4212AM*+ furnace: 58SU*B060M17**16AHRI reference: 21564097515.207.80190002.26EPA 3956702 →
CSAH*4212AM*+ furnace: 58TP*B090V21**20AHRI reference: 21564129715.207.80191002.26EPA 3956749 →
CSAH*4212AM*+ furnace: 58TP*B110V21**22AHRI reference: 21564132115.207.80190002.26EPA 3956751 →
CSAH*4812AM*+ furnace: 59TP6C100V21**20AHRI reference: 21564290315.208.10191002.26EPA 3956773 →
CSAH*4812AM*+ furnace: GG96VTAB60100C**AHRI reference: 21564290415.208.10191002.26EPA 3956776 →
CSAH*4812AM*+ furnace: 59TP6C100V21**22AHRI reference: 21564293315.208.10191002.26EPA 3956803 →
CSAH*4812AM*+ furnace: GG96VTAB66120D**AHRI reference: 21564295415.208.10193002.24EPA 3956820 →
CSAH*4812AM*+ furnace: 59TP6C120V24**22AHRI reference: 21564295215.208.10193002.24EPA 3956826 →
CSAH*4812AM*+ furnace: OVLAAB060154AHRI reference: 21564297815.208.10191002.26EPA 3956838 →
CSAH*4212AM*+ furnace: 59CU5B100C21**22AHRI reference: 21564141315.207.80190002.26EPA 3956858 →
CSAH*4212AM*+ furnace: 58TP*B135V24**22AHRI reference: 21564134715.207.80190002.26EPA 3956864 →
CSAH*4212AM*+ furnace: 59TP6C100V21**22AHRI reference: 21564188615.207.80188002.26EPA 3956876 →
CSAH*4212AM*+ furnace: OVLAAB060154AHRI reference: 21564193315.208.10191002.26EPA 3956885 →
CSAH*4812AM*+ furnace: 58SP*B090V21**20AHRI reference: 21564207015.208.10192002.24EPA 3956905 →
CSAH*4812AM*+ furnace: 58SP*B110V21**22AHRI reference: 21564209015.208.10191002.26EPA 3957100 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.