Carrier / AIR-SOURCE HEAT PUMP

27TPA824A**30*

2-STAGE 18 SEER HP · source records, page 7

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA824A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: GG96VTAB48080B**AHRI reference: 21564765517.508.10111002.08EPA 3960092
CAA**3717AM*+ furnace: 59TN6C060C17**14AHRI reference: 21564750617.508.10111002.08EPA 3960209
CAA**3717AM*+ furnace: 59TN6C080C17**14AHRI reference: 21564752917.508.10110002.10EPA 3960223
CAA**3717AM*+ furnace: 59SP6B080V17**16AHRI reference: 21564741017.508.10111002.08EPA 3960339
CAA**3721AM*+ furnace: 58TN*B090C21**20AHRI reference: 21564802617.508.10111002.10EPA 3960613
CAA**3721AM*+ furnace: 58TN*B110C21**20AHRI reference: 21564804717.508.10111002.10EPA 3960624
CAA**3721AM*+ furnace: 58TP*B090V21**20AHRI reference: 21564810317.508.10111002.10EPA 3960662
CAA**3721AM*+ furnace: 58SP*B070V17**16AHRI reference: 21564776617.508.10111002.10EPA 3960758
CAA**3721AM*+ furnace: 58SP*B090V21**20AHRI reference: 21564780417.508.10111002.10EPA 3960779
CAA**3721AM*+ furnace: 58SU*B100M21**20AHRI reference: 21564791817.508.10111002.10EPA 3960925
CAA**3721AM*+ furnace: 58TN*B045C17**12AHRI reference: 21564794617.508.10112002.08EPA 3961014
CAA**3721AM*+ furnace: 58TN*B070C21**20AHRI reference: 21564798617.508.10111002.10EPA 3961037
CAA**3721AM*+ furnace: 59TN6C100C21**22AHRI reference: 21564859317.508.10111002.10EPA 3961067
CAA**3721AM*+ furnace: 59TP6C080V17**16AHRI reference: 21564866517.508.10112002.08EPA 3961109
CAA**3721AM*+ furnace: 59CU5B060C17**16AHRI reference: 21564815117.508.10111002.10EPA 3961275
CAA**3721AM*+ furnace: 59CU5B080C21**20AHRI reference: 21564817117.508.10112002.10EPA 3961288
CAA**3721AM*+ furnace: 59CU5B100C21**22AHRI reference: 21564819117.508.10111002.10EPA 3961303
CAA**3721AM*+ furnace: 59MN7C060C17**14AHRI reference: 21564821217.508.10112002.10EPA 3961315
CAA**3721AM*+ furnace: 59MN7C060C21**20AHRI reference: 21564823317.508.50112002.10EPA 3961332
CAA**3721AM*+ furnace: 59MN7C080C17**14AHRI reference: 21564825417.508.10112002.08EPA 3961341

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →