Carrier / AIR-SOURCE HEAT PUMP

27TPA824A**30*

2-STAGE 18 SEER HP · source records, page 26

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA824A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3612AM*+ furnace: 59TN7A120C24**22AHRI reference: 21572121916.007.80110002.08EPA 3982038 →
CSAH*3612AM*+ furnace: 59TP7A100V21**20AHRI reference: 21572123316.007.80110002.08EPA 3982047 →
CSAH*3612AM*+ furnace: 59TP7A100V21**22AHRI reference: 21572125116.007.80109002.10EPA 3982064 →
CSAH*3612AM*+ furnace: 59TN6C040C14**10AHRI reference: 21565280116.008.00112002.05EPA 3996884 →
CSAH*3612AM*+ furnace: 59TP6C060V14**12AHRI reference: 21565297616.008.00111002.05EPA 3996895 →
CSAH*2412AM*+ furnace: OVMAAB036098AHRI reference: 21565023516.007.80111002.00EPA 3996920 →
CSAH*2412AM*+ furnace: 58TN*B135C24**22AHRI reference: 21564923016.008.00111002.05EPA 3996922 →
CSAH*2412AM*+ furnace: 58TN*B090C21**20AHRI reference: 21564919016.008.00111002.05EPA 3996954 →
CSAH*2412AM*+ furnace: 59SP6B080V21**20AHRI reference: 21564967516.008.00111002.05EPA 3996968 →
CSAH*3612AM*+ furnace: 59TP6C040V14**10AHRI reference: 21565292316.008.00112002.05EPA 3997026 →
CSAH*3612AM*+ furnace: GG96VTAB30040A**AHRI reference: 21565292516.008.00112002.05EPA 3997027 →
CSAH*3012AM*+ furnace: 58TN*B045C17**12AHRI reference: 21565054116.008.00111002.05EPA 3997035 →
CSAH*3612AM*+ furnace: 59SP6B060V14**12AHRI reference: 21565255516.008.00111002.05EPA 3997070 →
CSAH*3612AM*+ furnace: 59SP6B040V17**12AHRI reference: 21565253616.008.00112002.05EPA 3997090 →
CSAH*3612AM*+ furnace: 59SP6B040V14**10AHRI reference: 21565251616.008.00112002.05EPA 3997105 →
CSAH*2412AM*+ furnace: 58TP*B090V17**16AHRI reference: 21564931616.008.00111002.05EPA 3997131 →
CSAH*2412AM*+ furnace: 59MN7C060C21**20AHRI reference: 21564947316.008.00111002.05EPA 3997152 →
CSAH*2412AM*+ furnace: 59SU5B040M17**12AHRI reference: 21564973016.007.80112002.00EPA 3997185 →
CSAH*2412AM*+ furnace: 59TP6C080V21**20AHRI reference: 21565011816.008.00111002.05EPA 3997219 →
CSAH*2412AM*+ furnace: 59MN7C060C17**14AHRI reference: 21564945116.008.00111002.05EPA 3997237 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →