Carrier / AIR-SOURCE HEAT PUMP

27TPA824A**30*

2-STAGE 18 SEER HP · source records, page 16

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for 27TPA824A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2517AM*+ furnace: 59TN6C040C14**10AHRI reference: 21564489516.508.10113002.06EPA 3958142 →
CAA**2517AM*+ furnace: 59TP6C040V14**10AHRI reference: 21564496016.508.10113002.06EPA 3958182 →
CAA**2517AM*+ furnace: GG96VTAB30040A**AHRI reference: 21564496116.508.10113002.06EPA 3958183 →
CAA**2517AM*+ furnace: 59TP6C040V17**12AHRI reference: 21564498916.508.10113002.08EPA 3958193 →
CAA**3014AM*+ furnace: 59SP6B060V14**12AHRI reference: 21564528316.508.10109002.04EPA 3958375 →
CAA**3014AM*+ furnace: 59TP6C060V14**12AHRI reference: 21564535616.508.10109002.04EPA 3958410 →
CAA**3017AM*+ furnace: 58TN*B045C17**12AHRI reference: 21564553616.508.10111002.04EPA 3958568 →
CAA**3017AM*+ furnace: 59TP6C060V14**12AHRI reference: 21564602716.508.00111002.00EPA 3958608 →
CAA**3017AM*+ furnace: GG96VTAB48060B**AHRI reference: 21564605216.508.10110002.06EPA 3958615 →
CAA**3017AM*+ furnace: 59TP6C060V17**16AHRI reference: 21564605016.508.10110002.06EPA 3958618 →
CAA**3017AM*+ furnace: OVLAAB036098AHRI reference: 21564610816.508.10112002.02EPA 3958652 →
CAA**3017AM*+ furnace: 59MN7C060C17**14AHRI reference: 21564571516.508.10110002.04EPA 3958755 →
CAA**3017AM*+ furnace: 59SP6B060V14**12AHRI reference: 21564579616.508.00111002.00EPA 3958807 →
CAA**3017AM*+ furnace: 59SP6B060V17**16AHRI reference: 21564581416.508.10110002.06EPA 3958826 →
CAA**3017AM*+ furnace: 59SU5B040M17**12AHRI reference: 21564585016.508.00111002.05EPA 3958848 →
CAA**3017AM*+ furnace: OVMAAB036098AHRI reference: 21564612716.508.00112002.00EPA 3958881 →
CAA**3617AM*+ furnace: 59SP6B040V17**12AHRI reference: 21564656616.508.10111002.02EPA 3959262 →
CAA**3617AM*+ furnace: 59SP6B060V14**12AHRI reference: 21564658516.508.10111002.04EPA 3959281 →
CAA**3617AM*+ furnace: 59SU5B040M17**12AHRI reference: 21564664316.508.00110002.05EPA 3959404 →
CAA**3617AM*+ furnace: 59TP6C040V17**12AHRI reference: 21564678816.508.00111002.00EPA 3959507 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →