27SPA631A**30*
PERFORMANCE 16 SEER2 HP · source records, page 2
39 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27SPA631A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 39 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 39 / 39 |
| EER2 · BTU/Wh | 11.7–13 | 39 / 39 |
| HSPF2 · BTU/Wh | 7.8–8 | 39 / 39 |
| Cooling capacity · BTU/h | 27,400–29,400 | 39 / 39 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 39 / 39 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,200 | 39 / 39 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 39 / 39 |
| COP at 5°F / −15°C | 2–2.06 | 39 / 39 |
| Equipment / loop type | HP - Split System | 39 / 39 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 39 / 39 |
| Compressor staging | Single stage | 39 / 39 |
| Connected capability | No | 39 / 39 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**4321AM*+ furnace: 58CU*B080C21**20AHRI reference: 217691843 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4507023 → |
CAA**4321AM*+ furnace: 59SC2E080M21**20AHRI reference: 217692717 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507045 → |
CAA**4321AM*+ furnace: 59SC2E100M21**20AHRI reference: 217692740 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507069 → |
CAA**3721AM*+ furnace: 58SP*B110V21**22AHRI reference: 217690269 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507104 → |
CAA**3721AM*+ furnace: 58SU*B080M21**20AHRI reference: 217690339 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4507140 → |
CAA**4321AM*+ furnace: 59SC2E100M21**22AHRI reference: 217692767 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507182 → |
CAA**3721AM*+ furnace: 59SU5B100M21**22AHRI reference: 217691172 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507189 → |
CAA**4321AM*+ furnace: 58S(B,C)*B110M21**20AHRI reference: 217692062 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4507214 → |
CAA**4321AM*+ furnace: 58S(B,C)*B090M21**20AHRI reference: 217692037 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507222 → |
CAA**3721AM*+ furnace: 58SU*B060M17**16AHRI reference: 217690314 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507248 → |
CAA**4321AM*+ furnace: 58SP*B110V21**22AHRI reference: 217692149 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507266 → |
CAA**4321AM*+ furnace: 58SU*B060M17**16AHRI reference: 217692196 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507279 → |
CAA**4321AM*+ furnace: 58SU*B080M21**20AHRI reference: 217692223 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507313 → |
CAA**4321AM*+ furnace: 59TP6C100V21**22AHRI reference: 217693382 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4507340 → |
FEVA0036**+NAVA53601CKAHRI reference: 217702157 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4508694 → |
FEVB0036**+NAVA53601CKAHRI reference: 217702184 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4508844 → |
FM(C,U)5S36**AL*AHRI reference: 218452489 | 15.50 | 8.00 | 13500 | 2.00 | EPA 4624320 → |
FM(C,U)5S30**AL*AHRI reference: 218452470 | 15.50 | 8.00 | 13500 | 2.00 | EPA 4624339 → |
FMA5L30**AL*AHRI reference: 217683528 | 15.20 | 8.00 | 13800 | 2.00 | EPA 4506139 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →