Carrier / AIR-SOURCE HEAT PUMP

27SPA624A**30*

PERFORMANCE 16 SEER2 HP · source records, page 5

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 27SPA624A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 59SC2E080M17**16AHRI reference: 21420071715.507.80113002.10EPA 3407686
CVAMA3217XMA*+ furnace: 59TP6C080V17**16AHRI reference: 21420481615.507.80113001.98EPA 3407722
CVAMA3217XMA*+ furnace: GG96VTAB48080B**AHRI reference: 21420481715.507.80113001.98EPA 3407724
CAA**3721AM*+ furnace: 59SC6A100M21**22AHRI reference: 21420256415.507.80116002.14EPA 3407893
CVAVA3117XMA*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 21420497415.507.80113001.98EPA 3408055
CAA**3717AM*+ furnace: 59SC6A080M17**16AHRI reference: 21420081515.507.80113002.08EPA 3408084
CVAMA3117XMA*+ furnace: 59SU5B060M17**16AHRI reference: 21420416115.507.80113001.98EPA 3408130
CAA**3717AM*+ furnace: 58SU*B040M17**12AHRI reference: 21420007015.507.80113002.10EPA 3408243
CAA**3721AM*+ furnace: 58SP*B090V21**20AHRI reference: 21420170515.507.80116002.14EPA 3408403
CAA**3721AM*+ furnace: 58SU*B100M21**20AHRI reference: 21420173015.507.80116002.14EPA 3408428
CVAVA3817XMA*+ furnace: 59SP6B060V17**16AHRI reference: 21420760015.507.80114001.98EPA 3408482
CVAVA3817XMA*+ furnace: 59SP6B080V17**16AHRI reference: 21420762515.507.80113001.98EPA 3408497
CAA**3717AM*+ furnace: 59SU5B060M17**16AHRI reference: 21420101515.507.80113002.08EPA 3408525
CAA**3721AM*+ furnace: 58TN*B070C21**20AHRI reference: 21420189515.507.80116002.14EPA 3408565
CAA**3721AM*+ furnace: 58TN*B090C17**16AHRI reference: 21420192215.507.80115002.14EPA 3408593
CAA**3721AM*+ furnace: 58TN*B070C17**16AHRI reference: 21420186815.507.80115002.14EPA 3408616
CAA**3717AM*+ furnace: 58TN*B070C14**12AHRI reference: 21420015615.507.80112002.08EPA 3408627
CAA**3717AM*+ furnace: 58TN*B070C17**16AHRI reference: 21420018315.507.80113002.08EPA 3408654
CAA**3717AM*+ furnace: 58TN*B090C17**16AHRI reference: 21420021015.507.80113002.08EPA 3408681
CAA**3721AM*+ furnace: 59SP6B100V21**20AHRI reference: 21420274715.507.80116002.14EPA 3408713

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →