Carrier / AIR-SOURCE HEAT PUMP

27SPA624A**30*

PERFORMANCE 16 SEER2 HP · source records, page 10

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 27SPA624A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: GG96VTAB48060B**AHRI reference: 21420315515.207.80118002.12EPA 3407437
CAA**3721AM*+ furnace: GG96VTAB48080B**AHRI reference: 21420318615.207.80116002.12EPA 3407467
CAA**3721AM*+ furnace: 59TP6C080V17**16AHRI reference: 21420318515.207.80116002.12EPA 3407468
CAA**3717AM*+ furnace: 59SC2E060M14**12AHRI reference: 21420065715.207.80113002.08EPA 3407561
CAA**3717AM*+ furnace: 59SC6A060M17**16AHRI reference: 21420078115.207.80114002.08EPA 3407613
CAA**3717AM*+ furnace: 58SP*B045V14**12AHRI reference: 21419993115.207.80112002.08EPA 3407849
CAA**3721AM*+ furnace: 59SC6A060M17**16AHRI reference: 21420247015.207.80117002.12EPA 3407941
CAA**3721AM*+ furnace: 59SC6A080M17**16AHRI reference: 21420250215.207.80116002.12EPA 3407973
CAA**3717AM*+ furnace: 58SP*B070V14**12AHRI reference: 21419995615.207.80112002.08EPA 3408004
CAA**3717AM*+ furnace: 58SP*B070V17**16AHRI reference: 21419998115.207.80113002.08EPA 3408029
CAA**3721AM*+ furnace: 58SP*B070V17**16AHRI reference: 21420165415.207.80115002.14EPA 3408178
CAA**3717AM*+ furnace: 59SP6B060V17**16AHRI reference: 21420090115.207.80114002.08EPA 3408317
CAA**3717AM*+ furnace: 59SP6B080V17**16AHRI reference: 21420092615.207.80114002.08EPA 3408342
CAA**3721AM*+ furnace: 58SP*B090V17**16AHRI reference: 21420168015.207.80116002.14EPA 3408378
CAA**3721AM*+ furnace: 59SP6B060V17**16AHRI reference: 21420269715.207.80118002.12EPA 3408704
CAA**3721AM*+ furnace: 59SP6B080V17**16AHRI reference: 21420272215.207.80116002.12EPA 3408850
CAA**2517AM*+ furnace: 58CU*A040C17**12AHRI reference: 21421028015.207.80112002.12EPA 3409636
CAA**2517AM*+ furnace: 58S(B,C)*B070M14**12AHRI reference: 21421034115.207.80113002.12EPA 3409731
CAA**2517AM*+ furnace: 58SP*B070V14**12AHRI reference: 21421043515.207.80113002.12EPA 3410088
CAA**2517AM*+ furnace: 58SU*A040E17**12AHRI reference: 21421046015.207.80110002.08EPA 3410353