Carrier / AIR-SOURCE HEAT PUMP

27SCA524A**30*

COMFORT 15 SEER2 HP · source records, page 5

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for 27SCA524A**30*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA3217XMA*+ furnace: 59TP6C080V17**16AHRI reference: 21420481415.507.80113001.98EPA 3407721 →
CVAMA3217XMA*+ furnace: GG96VTAB48080B**AHRI reference: 21420481515.507.80113001.98EPA 3407723 →
CAA**3721AM*+ furnace: 59SC6A100M21**22AHRI reference: 21420256315.507.80116002.14EPA 3407891 →
CVAVA3117XMA*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 21420497315.507.80113001.98EPA 3408053 →
CAA**3717AM*+ furnace: 59SC6A080M17**16AHRI reference: 21420081415.507.80113002.08EPA 3408082 →
CVAMA3117XMA*+ furnace: 59SU5B060M17**16AHRI reference: 21420416015.507.80113001.98EPA 3408128 →
CAA**3717AM*+ furnace: 58SU*B040M17**12AHRI reference: 21420006915.507.80113002.10EPA 3408242 →
CAA**3721AM*+ furnace: 58SP*B090V21**20AHRI reference: 21420170415.507.80116002.14EPA 3408401 →
CAA**3721AM*+ furnace: 58SU*B100M21**20AHRI reference: 21420172915.507.80116002.14EPA 3408427 →
CVAVA3817XMA*+ furnace: 59SP6B060V17**16AHRI reference: 21420759915.507.80114001.98EPA 3408481 →
CVAVA3817XMA*+ furnace: 59SP6B080V17**16AHRI reference: 21420762415.507.80113001.98EPA 3408494 →
CAA**3717AM*+ furnace: 59SU5B060M17**16AHRI reference: 21420101415.507.80113002.08EPA 3408524 →
CAA**3721AM*+ furnace: 58TN*B070C21**20AHRI reference: 21420189415.507.80116002.14EPA 3408564 →
CAA**3721AM*+ furnace: 58TN*B090C17**16AHRI reference: 21420192115.507.80115002.14EPA 3408592 →
CAA**3721AM*+ furnace: 58TN*B070C17**16AHRI reference: 21420186715.507.80115002.14EPA 3408615 →
CAA**3717AM*+ furnace: 58TN*B070C14**12AHRI reference: 21420015515.507.80112002.08EPA 3408626 →
CAA**3717AM*+ furnace: 58TN*B070C17**16AHRI reference: 21420018215.507.80113002.08EPA 3408652 →
CAA**3717AM*+ furnace: 58TN*B090C17**16AHRI reference: 21420020915.507.80113002.08EPA 3408679 →
CAA**3721AM*+ furnace: 59SP6B100V21**20AHRI reference: 21420274615.507.80116002.14EPA 3408711 →
CVAMA3117XMA*+ furnace: 58S(B,C)*B070M17**16AHRI reference: 21420348015.507.80113001.98EPA 3408733 →