Carrier / AIR-SOURCE HEAT PUMP

25VNA837A*031*+TSTAT

INFINITY 18VS HEAT PUMP 2-STAGE

83 published source records · source checked Sep 21, 2026

SEER2 range17–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,600–33,000BTU/h

Each efficiency range summarizes published EPA records for 25VNA837A*031*+TSTAT. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 83 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–1883 / 83
EER2 · BTU/Wh11.7–1283 / 83
HSPF2 · BTU/Wh8.1–8.583 / 83
Cooling capacity · BTU/h31,600–33,00083 / 83
Heating capacity at 47°F / 8.3°C · BTU/h46,000–48,00083 / 83
Heating capacity at 17°F / −8.3°C · BTU/h30,200–31,00083 / 83
Heating capacity at 5°F / −15°C · BTU/h8,000–24,40083 / 83
COP at 5°F / −15°C1.94–1.9883 / 83
Equipment / loop typeHP - Split System83 / 83
Refrigerant / source-reported GWPR-410A (GWP:2088)83 / 83
Compressor stagingTwo-stage83 / 83
Connected capabilityNo83 / 83

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CNPV*6024AL*+ furnace: 58SP*A090V24**20AHRI reference: 21046498918.008.10242001.96EPA 2416851 →
CNPV*6024AL*+ furnace: 58TP*A135V24**22AHRI reference: 21046502218.008.10240001.94EPA 2417231 →
CNPV*6024AL*+ furnace: 59TP6B100V21**22AHRI reference: 21046493318.008.10240001.94EPA 2417635 →
CNPV*6024AL*+ furnace: GG96VTAA60100CAHRI reference: 21046493418.008.10240001.94EPA 2417647 →
CAP**6121AL*+ furnace: 58SP*A090V21**20AHRI reference: 21046141118.008.1080001.98EPA 2631961 →
CAP**6121AL*+ furnace: 59TP6B100V21**22AHRI reference: 21046132218.008.10242001.96EPA 2631962 →
CAP**6124AL*+ furnace: 58TP*A090V21**20AHRI reference: 21046183418.008.1080001.98EPA 2631966 →
CAP**6124AL*+ furnace: 59TP6B080V21**20AHRI reference: 21046195818.008.1080001.98EPA 2631970 →
CAP**6124AL*+ furnace: 59TP6B120V24**22AHRI reference: 21046184718.008.10242001.96EPA 2631971 →
CAP**6124AL*+ furnace: 59TP6B100V21**22AHRI reference: 21046175618.008.1080001.98EPA 2631975 →
CAP**6124AL*+ furnace: 58SP*A090V21**20AHRI reference: 21046180118.008.1080001.98EPA 2631978 →
CAP**6121AL*+ furnace: 58TP*A090V17**16AHRI reference: 21046142218.008.10242001.96EPA 2631979 →
CAP**6124AL*+ furnace: 58TP*A135V24**22AHRI reference: 21046184518.008.10242001.96EPA 2631982 →
CAP**6124AL*+ furnace: 59SP6A120V24**22AHRI reference: 21046174518.008.1080001.98EPA 2631983 →
CAP**6124AL*+ furnace: 59SP6A100V21**20AHRI reference: 21046173418.008.10242001.96EPA 2631984 →
CAP**6121AL*+ furnace: 58TP*A090V21**20AHRI reference: 21046142418.008.1080001.98EPA 2631989 →
CAP**6024AL*+ furnace: 59TP6B100V21**22AHRI reference: 21046097718.008.10242001.96EPA 2632332 →
CAP**6124AL*+ furnace: 59TP6B100V21**20AHRI reference: 21046196918.008.10242001.96EPA 2632370 →
CAP**6124AL*+ furnace: GG96VTAA66120DAHRI reference: 21046184818.008.10242001.96EPA 2633615 →
CAP**6121AL*+ furnace: GG96VTAA60100CAHRI reference: 21046132318.008.10242001.96EPA 2633616 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.