CanAir / AIR-SOURCE HEAT PUMP

4C25SCH12H21

4C Series · 4C22 Series

9 published source records · source checked Sep 21, 2026

SEER2 range19–25.5BTU/Wh
HSPF2 range10–11.5BTU/Wh
Cooling capacity11,500–12,000BTU/h

Each efficiency range summarizes published EPA records for 4C25SCH12H21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 9 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19–25.59 / 9
EER2 · BTU/Wh11.7–139 / 9
HSPF2 · BTU/Wh10–11.59 / 9
Cooling capacity · BTU/h11,500–12,0009 / 9
Heating capacity at 47°F / 8.3°C · BTU/h12,0009 / 9
Heating capacity at 17°F / −8.3°C · BTU/h8,500–10,4009 / 9
Heating capacity at 5°F / −15°C · BTU/h8,400–8,9009 / 9
COP at 5°F / −15°C2.25–2.59 / 9
Equipment / loop typeHP - Mini or Multi Split9 / 9
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)9 / 9
Compressor stagingContinuously variable9 / 9
Connected capabilityNo9 / 9

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4C28SEH12H21Cold climate designationAHRI reference: 21582838825.5010.6084002.30EPA 3712099
4C28SEC12H21Cold climate designationAHRI reference: 21795897924.6011.0089002.50EPA 4514416
4C25SEH12H21Cold climate designationAHRI reference: 21795892223.1011.5086002.35EPA 4514363
4C25SEH12H21-PCold climate designationAHRI reference: 21800056623.1011.5086002.35EPA 4515411
4C25SEH12H21-NCold climate designationAHRI reference: 21800057023.1011.5086002.35EPA 4515415
4C28SEOC12H21Cold climate designationAHRI reference: 21795894122.1010.0086002.48EPA 4514380
4C28SEQ12H21Cold climate designationAHRI reference: 21795894821.1010.4084002.40EPA 4514387
4C28SEDH12H21Cold climate designationAHRI reference: 21795896619.5010.5089002.44EPA 4514405
4C28SEDL12H21Cold climate designationAHRI reference: 21795896019.0010.2088002.25EPA 4514399

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →