CanAir / AIR-SOURCE HEAT PUMP

4C25SCH09H21

4C Series · 4C22 Series

8 published source records · source checked Sep 21, 2026

SEER2 range19.5–25.8BTU/Wh
HSPF2 range11–13BTU/Wh
Cooling capacity9,000BTU/h

Each efficiency range summarizes published EPA records for 4C25SCH09H21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 8 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19.5–25.88 / 8
EER2 · BTU/Wh12.8–14.98 / 8
HSPF2 · BTU/Wh11–138 / 8
Cooling capacity · BTU/h9,0008 / 8
Heating capacity at 47°F / 8.3°C · BTU/h10,000–11,0008 / 8
Heating capacity at 17°F / −8.3°C · BTU/h7,900–9,3008 / 8
Heating capacity at 5°F / −15°C · BTU/h8,000–8,6008 / 8
COP at 5°F / −15°C2.17–2.368 / 8
Equipment / loop typeHP - Mini or Multi Split8 / 8
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)8 / 8
Compressor stagingContinuously variable8 / 8
Connected capabilityNo8 / 8

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4C28SEH09H21Cold climate designationAHRI reference: 21582838725.8012.5080002.36EPA 3712100
4C25SEH09H21Cold climate designationAHRI reference: 21795892124.6013.0082002.33EPA 4514362
4C25SEH09H21-PCold climate designationAHRI reference: 21800056524.6013.0082002.33EPA 4515410
4C25SEH09H21-NCold climate designationAHRI reference: 21800056924.6013.0082002.33EPA 4515413
4C28SEOC12H21Cold climate designationAHRI reference: 21795894022.1011.8080002.18EPA 4514379
4C28SEQ09H21Cold climate designationAHRI reference: 21795894721.6011.3083002.17EPA 4514386
4C28SEDH09H21Cold climate designationAHRI reference: 21795896519.7011.5083002.31EPA 4514404
4C28SEDL09H21Cold climate designationAHRI reference: 21795895919.5011.0086002.25EPA 4514398

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →