BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN560**AA*

2-STAGE 18 SEER HP · source records, page 5

127 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN560**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5127 / 127
EER2 · BTU/Wh11.7–13127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h54,000–58,000127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500127 / 127
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800127 / 127
COP at 5°F / −15°C2.1–2.34127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingTwo-stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6121AM*+ furnace: 986TD66100C21***AHRI reference: 21562991916.008.00304002.25EPA 3951151 →
CAA**6024AM*+ furnace: 987MC66100C21***AHRI reference: 21562928116.008.00300002.25EPA 3951163 →
CAA**6024AM*+ furnace: 926SB60080V21***AHRI reference: 21562930916.008.00300002.25EPA 3951178 →
CAA**6024AM*+ furnace: 926SB60100V21***AHRI reference: 21562932216.008.00298002.25EPA 3951194 →
CAA**6024AM*+ furnace: 926SB66120V24***AHRI reference: 21562933516.008.00298002.25EPA 3951212 →
CAA**6024AM*+ furnace: 935SB60080M21***AHRI reference: 21562934816.008.00300002.25EPA 3951231 →
CAA**6121AM*+ furnace: 926TC60080V21***AHRI reference: 21562993316.008.00304002.25EPA 3951262 →
CAA**6121AM*+ furnace: 926TC60100V21***AHRI reference: 21562995116.008.00302002.30EPA 3951285 →
CAA**6124AM*+ furnace: 82*SB60090V21***AHRI reference: 21563001016.008.00300002.25EPA 3951287 →
CAA**6024AM*+ furnace: 935SB60100M21***AHRI reference: 21562936716.008.00300002.25EPA 3951302 →
CAA**6024AM*+ furnace: 935SB66100M21***AHRI reference: 21562938616.008.00296002.30EPA 3951326 →
CAA**6024AM*+ furnace: 986TD66100C21***AHRI reference: 21562941416.008.00300002.25EPA 3951340 →
CAA**6024AM*+ furnace: 986TD66120C24***AHRI reference: 21562942816.008.00298002.25EPA 3951355 →
CAA**6024AM*+ furnace: 926TC60080V21***AHRI reference: 21562944216.008.00300002.25EPA 3951367 →
CAA**6124AM*+ furnace: 88*TB60070C21***AHRI reference: 21563008716.008.00306002.25EPA 3951447 →
CAA**6024AM*+ furnace: 926TC60100V21***AHRI reference: 21562946016.008.00298002.25EPA 3951458 →
CAA**6024AM*+ furnace: 926TC66100V21***AHRI reference: 21562947816.008.00296002.30EPA 3951475 →
CAA**6024AM*+ furnace: 926TC66120V24***AHRI reference: 21562949316.008.00300002.25EPA 3951489 →
CAA**6024AM*+ furnace: OVLAAB060154AHRI reference: 21562950916.008.00302002.25EPA 3951507 →
CAA**6121AM*+ furnace: 82*SB60090V21***AHRI reference: 21562956516.008.00300002.30EPA 3951520 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →