BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN560**AA*

2-STAGE 18 SEER HP · source records, page 5

127 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN560**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5127 / 127
EER2 · BTU/Wh11.7–13127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h54,000–58,000127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500127 / 127
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800127 / 127
COP at 5°F / −15°C2.1–2.34127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingTwo-stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6121AM*+ furnace: 986TD66100C21***AHRI reference: 21562991916.008.00304002.25EPA 3951151
CAA**6024AM*+ furnace: 987MC66100C21***AHRI reference: 21562928116.008.00300002.25EPA 3951163
CAA**6024AM*+ furnace: 926SB60080V21***AHRI reference: 21562930916.008.00300002.25EPA 3951178
CAA**6024AM*+ furnace: 926SB60100V21***AHRI reference: 21562932216.008.00298002.25EPA 3951194
CAA**6024AM*+ furnace: 926SB66120V24***AHRI reference: 21562933516.008.00298002.25EPA 3951212
CAA**6024AM*+ furnace: 935SB60080M21***AHRI reference: 21562934816.008.00300002.25EPA 3951231
CAA**6121AM*+ furnace: 926TC60080V21***AHRI reference: 21562993316.008.00304002.25EPA 3951262
CAA**6121AM*+ furnace: 926TC60100V21***AHRI reference: 21562995116.008.00302002.30EPA 3951285
CAA**6124AM*+ furnace: 82*SB60090V21***AHRI reference: 21563001016.008.00300002.25EPA 3951287
CAA**6024AM*+ furnace: 935SB60100M21***AHRI reference: 21562936716.008.00300002.25EPA 3951302
CAA**6024AM*+ furnace: 935SB66100M21***AHRI reference: 21562938616.008.00296002.30EPA 3951326
CAA**6024AM*+ furnace: 986TD66100C21***AHRI reference: 21562941416.008.00300002.25EPA 3951340
CAA**6024AM*+ furnace: 986TD66120C24***AHRI reference: 21562942816.008.00298002.25EPA 3951355
CAA**6024AM*+ furnace: 926TC60080V21***AHRI reference: 21562944216.008.00300002.25EPA 3951367
CAA**6124AM*+ furnace: 88*TB60070C21***AHRI reference: 21563008716.008.00306002.25EPA 3951447
CAA**6024AM*+ furnace: 926TC60100V21***AHRI reference: 21562946016.008.00298002.25EPA 3951458
CAA**6024AM*+ furnace: 926TC66100V21***AHRI reference: 21562947816.008.00296002.30EPA 3951475
CAA**6024AM*+ furnace: 926TC66120V24***AHRI reference: 21562949316.008.00300002.25EPA 3951489
CAA**6024AM*+ furnace: OVLAAB060154AHRI reference: 21562950916.008.00302002.25EPA 3951507
CAA**6121AM*+ furnace: 82*SB60090V21***AHRI reference: 21562956516.008.00300002.30EPA 3951520