BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 7

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6121XMA*+ furnace: 83*CB60100C21***AHRI reference: 21572232517.008.00252002.24EPA 3982532
CVAVA6121XMA*+ furnace: 987TA66100C21***AHRI reference: 21572235317.008.00254002.10EPA 3982566
CVAVA6121XMA*+ furnace: 927TA60080V21***AHRI reference: 21572236717.008.00250002.10EPA 3982571
CVAVA6121XMA*+ furnace: 927TA60100V21***AHRI reference: 21572238317.008.00250002.12EPA 3982593
CVAVA6124XMA*+ furnace: 987TA66100C21***AHRI reference: 21572245617.008.00252002.12EPA 3982666
CVAVA6124XMA*+ furnace: 987TA66120C24***AHRI reference: 21572247017.008.00252002.12EPA 3982674
CVAVA6124XMA*+ furnace: 927TA60080V21***AHRI reference: 21572248417.008.00256002.10EPA 3982697
CVAVA6124XMA*+ furnace: 927TA60100V21***AHRI reference: 21572250017.008.00252002.12EPA 3982709
CVAMA4821XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562291016.508.10244002.12EPA 3947315
CVAMA4821XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562292316.508.10244002.14EPA 3947329
CVAMA4821XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562293616.508.10246002.12EPA 3947342
CVAMA4821XMA*+ furnace: 83*SB60100M21***AHRI reference: 21562297416.508.10246002.12EPA 3947381
CVAMA4821XMA*+ furnace: 88*TB60090C21***AHRI reference: 21562300716.508.10244002.14EPA 3947410
CVAMA4821XMA*+ furnace: 88*TB60110C21***AHRI reference: 21562302116.508.10244002.12EPA 3947425
CVAMA4821XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562303516.508.10244002.12EPA 3947444
CVAMA4821XMA*+ furnace: 82*TB66110V21***AHRI reference: 21562305116.508.10244002.14EPA 3947456
CVAMA4821XMA*+ furnace: 935SB60100M21***AHRI reference: 21562315716.508.10244002.12EPA 3947501
CVAMA4821XMA*+ furnace: 935SB66100M21***AHRI reference: 21562317616.508.10246002.12EPA 3947520
CVAMA4821XMA*+ furnace: 926TC66100V21***AHRI reference: 21562325416.508.10242002.12EPA 3947578
CVAMA4921XMA*+ furnace: 88*TB60070C21***AHRI reference: 21562335016.508.10256002.08EPA 3947674

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →