BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 4

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA6021XMA*+ furnace: 986TD60080C21***AHRI reference: 21562397217.008.10252002.10EPA 3948582 →
CVAMA6021XMA*+ furnace: 986TD66100C21***AHRI reference: 21562398617.008.10252002.10EPA 3948596 →
CVAVA4821XMA*+ furnace: 926TC66100V21***AHRI reference: 21562441617.008.10240002.16EPA 3948654 →
CVAVA4924XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562442917.008.10250002.10EPA 3948668 →
CVAVA4924XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562444217.008.10250002.10EPA 3948681 →
CVAVA4924XMA*+ furnace: 82*SB66135V24***AHRI reference: 21562445517.008.10250002.10EPA 3948694 →
CVAVA4924XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562450117.008.10250002.10EPA 3948742 →
CVAVA4924XMA*+ furnace: 82*TB66135V24***AHRI reference: 21562453517.008.10248002.12EPA 3948775 →
CVAVA4924XMA*+ furnace: 935SB66100M21***AHRI reference: 21562462917.008.10248002.12EPA 3948856 →
CVAVA6021XMA*+ furnace: 82*TB66110V21***AHRI reference: 21562482717.008.10244002.14EPA 3948874 →
CVAVA6021XMA*+ furnace: 987MC60080C21***AHRI reference: 21562487317.008.10252002.08EPA 3948907 →
CVAVA4924XMA*+ furnace: 926TC66100V21***AHRI reference: 21562470717.008.50248002.12EPA 3948993 →
CVAVA6021XMA*+ furnace: 935SB60100M21***AHRI reference: 21562493217.008.10248002.12EPA 3949012 →
CVAVA6021XMA*+ furnace: 83*CA60100C21***AHRI reference: 21562472017.008.10252002.10EPA 3949056 →
CVAVA6021XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562473417.008.10244002.12EPA 3949068 →
CVAVA6021XMA*+ furnace: 986TD60080C21***AHRI reference: 21562495117.008.10252002.10EPA 3949093 →
CVAVA6021XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562474717.008.10250002.10EPA 3949153 →
CVAVA6021XMA*+ furnace: 83*SB60100M21***AHRI reference: 21562476617.008.10248002.12EPA 3949173 →
CVAVA6021XMA*+ furnace: 88*TB60090C21***AHRI reference: 21562479917.008.10246002.12EPA 3949204 →
CVAVA6021XMA*+ furnace: 88*TB60110C21***AHRI reference: 21562481317.008.10250002.10EPA 3949216 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →