PH8TAN548**AA*
2-STAGE 18 SEER HP
417 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 417 / 417 |
| EER2 · BTU/Wh | 11.7–13.5 | 417 / 417 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 417 / 417 |
| Cooling capacity · BTU/h | 45,500–50,500 | 417 / 417 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 417 / 417 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 417 / 417 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 417 / 417 |
| COP at 5°F / −15°C | 2.06–2.32 | 417 / 417 |
| Equipment / loop type | HP - Split System | 417 / 417 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 417 / 417 |
| Compressor staging | Two-stage | 417 / 417 |
| Connected capability | No | 417 / 417 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FG5ANBD60L*AHRI reference: 215560714 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982807 → |
FT5ANBD60L*AHRI reference: 215560713 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982808 → |
PF5TNBD60L*AHRI reference: 215560715 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982811 → |
FT5BD6021X*AHRI reference: 218695443 | 18.00 | 8.50 | 25800 | 2.32 | EPA 4683384 → |
CVAMA4921XMA*+ furnace: 83*SB60080M21***AHRI reference: 215623312 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3947635 → |
CVAMA6021XMA*+ furnace: 926TC66100V21***AHRI reference: 215624036 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948039 → |
CVAMA6021XMA*+ furnace: 83*SB60080M21***AHRI reference: 215623710 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948271 → |
CVAVA4924XMA*+ furnace: 83*SB60080M21***AHRI reference: 215624468 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3948710 → |
CVAVA6021XMA*+ furnace: 926TC66100V21***AHRI reference: 215625001 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3949142 → |
CVAVA6121XMA*+ furnace: 82*SB66110V21***AHRI reference: 215625027 | 17.50 | 8.50 | 24800 | 2.26 | EPA 3949237 → |
CVAVA6121XMA*+ furnace: 83*SB48060M17***AHRI reference: 215625040 | 17.50 | 8.10 | 25000 | 2.12 | EPA 3949250 → |
CVAVA6121XMA*+ furnace: 83*SB60080M21***AHRI reference: 215625059 | 17.50 | 8.50 | 24400 | 2.30 | EPA 3949271 → |
CVAVA6121XMA*+ furnace: 83*SB60100M21***AHRI reference: 215625078 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949290 → |
CVAVA6121XMA*+ furnace: 88*TB60090C21***AHRI reference: 215625111 | 17.50 | 8.50 | 25200 | 2.24 | EPA 3949323 → |
CVAVA6121XMA*+ furnace: 88*TB60110C21***AHRI reference: 215625125 | 17.50 | 8.50 | 25000 | 2.24 | EPA 3949339 → |
CVAVA6124XMA*+ furnace: 82*SB66135V24***AHRI reference: 215625410 | 17.50 | 8.50 | 25200 | 2.24 | EPA 3949356 → |
CVAVA6124XMA*+ furnace: 935SB66100M21***AHRI reference: 215625659 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949432 → |
CVAVA6121XMA*+ furnace: 82*TB66110V21***AHRI reference: 215625155 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3949457 → |
CVAVA6121XMA*+ furnace: 935SB66100M21***AHRI reference: 215625293 | 17.50 | 8.10 | 24400 | 2.16 | EPA 3949593 → |
CVAVA6124XMA*+ furnace: 82*TB66135V24***AHRI reference: 215625518 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949637 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →