BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN536**AA*

2-STAGE 18 SEER HP · source records, page 3

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA4821XMA*+ furnace: 82*SB66110V21***AHRI reference: 21561950415.507.80177001.78EPA 3946286 →
CVAMA4821XMA*+ furnace: 83*SB48060M17***AHRI reference: 21561951715.507.80177001.78EPA 3946310 →
CVAMA4821XMA*+ furnace: 935CB66100C21***AHRI reference: 21561967215.507.80178001.78EPA 3946365 →
CVAMA4821XMA*+ furnace: 986TD60080C21***AHRI reference: 21561977115.507.80178001.78EPA 3946433 →
CVAMA4821XMA*+ furnace: 926TC60100V21***AHRI reference: 21561984315.507.80178001.78EPA 3946463 →
CVAVA3817XMA*+ furnace: 83*CA36040C17***AHRI reference: 21562125815.507.80178001.80EPA 3946465 →
CVAVA3817XMA*+ furnace: 82*SB48070V17***AHRI reference: 21562129915.507.80177001.78EPA 3946491 →
CVAMA4821XMA*+ furnace: 926TC66100V21***AHRI reference: 21561986115.507.80176001.80EPA 3946519 →
CVAMA4921XMA*+ furnace: 82*SB48090V17***AHRI reference: 21561987415.507.80180001.78EPA 3946530 →
CVAMA4921XMA*+ furnace: 88*TB48090C17***AHRI reference: 21561991915.507.80180001.78EPA 3946574 →
CVAMA4921XMA*+ furnace: 88*TB60090C21***AHRI reference: 21561993315.507.80178001.82EPA 3946587 →
CVAMA4921XMA*+ furnace: 82*TB48090V17***AHRI reference: 21561996315.507.80180001.78EPA 3946618 →
CVAVA3721XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562091815.507.80177001.80EPA 3946695 →
CVAVA3721XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562093115.507.80177001.78EPA 3946707 →
CVAVA3721XMA*+ furnace: 986TD60080C21***AHRI reference: 21562115515.507.80178001.78EPA 3946721 →
CVAVA3721XMA*+ furnace: 926TC66100V21***AHRI reference: 21562124515.507.80176001.80EPA 3946772 →
CVAVA3721XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562094415.507.80177001.78EPA 3946791 →
CVAVA3721XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562102615.507.80177001.80EPA 3946812 →
CVAVA3721XMA*+ furnace: 935CB66100C21***AHRI reference: 21562105615.507.80178001.78EPA 3946826 →
CVAVA3817XMA*+ furnace: 88*TB48070C17***AHRI reference: 21562139115.507.80177001.78EPA 3946913 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →