BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN536**AA*

2-STAGE 18 SEER HP · source records, page 12

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**4321AM*+ furnace: 926TC48080V17***AHRI reference: 21563854015.208.10196002.24EPA 3955652
CAA**4321AM*+ furnace: 935SB48060M17***AHRI reference: 21563831315.208.10196002.22EPA 3955705
CAA**4821AM*+ furnace: 82*SB48090V17***AHRI reference: 21563876915.208.10191002.26EPA 3955795
CAA**4321AM*+ furnace: 935CB48060C17***AHRI reference: 21563806615.208.10194002.24EPA 3955905
CAA**4321AM*+ furnace: 987MC42080C17***AHRI reference: 21563817315.208.10195002.24EPA 3955949
CAA**4321AM*+ furnace: 986TD42080C17***AHRI reference: 21563844315.208.10194002.24EPA 3956035
CAA**4821AM*+ furnace: 83*CA36040C17***AHRI reference: 21563868515.208.10193002.22EPA 3956070
CAA**4821AM*+ furnace: 83*CA60080C21***AHRI reference: 21563872815.208.10192002.24EPA 3956085
CAA**4821AM*+ furnace: 82*SB48070V17***AHRI reference: 21563874915.208.10192002.24EPA 3956099
CAA**4821AM*+ furnace: 88*TB48070C17***AHRI reference: 21563896215.208.10193002.24EPA 3956159
CAA**4821AM*+ furnace: 88*TB60070C21***AHRI reference: 21563898515.208.10192002.26EPA 3956179
CAA**4821AM*+ furnace: 88*TB48090C17***AHRI reference: 21563900615.208.10191002.26EPA 3956193
CAA**4821AM*+ furnace: 82*TB48090V17***AHRI reference: 21563908815.208.10191002.26EPA 3956226
CAA**4821AM*+ furnace: 82*TB48070V17***AHRI reference: 21563906615.208.10193002.24EPA 3956239
CAA**4821AM*+ furnace: 935CB60080C21***AHRI reference: 21563917815.208.10192002.26EPA 3956293
CAA**4821AM*+ furnace: 926SB60080V21***AHRI reference: 21563937815.208.10192002.24EPA 3956345
CAA**4821AM*+ furnace: 935SB60080M21***AHRI reference: 21563947415.208.10192002.24EPA 3956372
CAA**4821AM*+ furnace: 926TC60080V21***AHRI reference: 21563969815.208.10192002.24EPA 3956409
CSAH*3612AM*+ furnace: 83*SB60080M21***AHRI reference: 21564001015.207.80188002.26EPA 3956502
CSAH*3612AM*+ furnace: 926TC66100V21***AHRI reference: 21564067715.207.80190002.24EPA 3956529