BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN536**AA*

2-STAGE 18 SEER HP

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FT5ANBD60L*AHRI reference: 21562894417.008.50186002.48EPA 3950880
PF5TNBD60L*AHRI reference: 21562894617.008.50186002.48EPA 3950882
FG5ANBD60L*AHRI reference: 21562894517.008.50186002.48EPA 3950883
PF5TNXC48L*AHRI reference: 21562889216.508.10187002.30EPA 3950430
FT5AN(B,X)C48L*AHRI reference: 21562889016.508.10187002.30EPA 3950432
FG5ANXC48L*AHRI reference: 21562889116.508.10187002.30EPA 3950433
FT5BD4821X*AHRI reference: 21869540916.508.10184002.24EPA 4683418
CVAMA4821XMA*+ furnace: 83*SB60080M21***AHRI reference: 21561953616.008.00175001.90EPA 3946329
CVAMA4921XMA*+ furnace: 82*SB60090V21***AHRI reference: 21561988716.008.00179001.90EPA 3946543
CVAMA4921XMA*+ furnace: 83*SB60080M21***AHRI reference: 21561990016.008.00177001.95EPA 3946554
CVAMA4921XMA*+ furnace: 82*TB60090V21***AHRI reference: 21561997316.008.00179001.90EPA 3946629
CVAMA4921XMA*+ furnace: 935CB66100C21***AHRI reference: 21562000316.008.00179001.95EPA 3946646
CVAMA4921XMA*+ furnace: 986TD60080C21***AHRI reference: 21562004416.007.80179001.80EPA 3946659
CVAMA4921XMA*+ furnace: 926TC60100V21***AHRI reference: 21562008016.008.00179001.90EPA 3946674
CVAVA3817XMA*+ furnace: 82*SB48090V17***AHRI reference: 21562131216.008.00176001.90EPA 3946863
CVAVA3817XMA*+ furnace: 83*SB36040M17***AHRI reference: 21562132516.008.00176001.85EPA 3946878
CVAVA3817XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562134416.008.00176001.90EPA 3946893
CVAVA3817XMA*+ furnace: 88*TB48090C17***AHRI reference: 21562140516.007.80176001.80EPA 3946927
CVAVA3817XMA*+ furnace: 82*TB48090V17***AHRI reference: 21562144516.008.00176001.90EPA 3946974
CAA**3721AM*+ furnace: 82*SB66110V21***AHRI reference: 21563568616.008.10194002.24EPA 3954582

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →