PH8TAN524**AA*
2-STAGE 18 SEER HP · source records, page 7
541 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 541 / 541 |
| EER2 · BTU/Wh | 11.5–14 | 541 / 541 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 541 / 541 |
| Cooling capacity · BTU/h | 22,200–25,000 | 541 / 541 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–25,400 | 541 / 541 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,100–15,000 | 541 / 541 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,700–11,500 | 541 / 541 |
| COP at 5°F / −15°C | 1.9–2.24 | 541 / 541 |
| Equipment / loop type | HP - Split System | 541 / 541 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 541 / 541 |
| Compressor staging | Two-stage | 541 / 541 |
| Connected capability | No | 541 / 541 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3721AM*+ furnace: 83*SB60100M21***AHRI reference: 215647927 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3960998 → |
CAA**3721AM*+ furnace: 88*TB36045C17***AHRI reference: 215647952 | 17.50 | 8.10 | 11200 | 2.08 | EPA 3961015 → |
CAA**3721AM*+ furnace: 88*TB60070C21***AHRI reference: 215647992 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961039 → |
CAA**3721AM*+ furnace: 88*TB60090C21***AHRI reference: 215648032 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961063 → |
CAA**3721AM*+ furnace: 986TD66100C21***AHRI reference: 215648599 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961071 → |
CAA**3721AM*+ furnace: 935CB48060C17***AHRI reference: 215648156 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961277 → |
CAA**3721AM*+ furnace: 935CB60080C21***AHRI reference: 215648177 | 17.50 | 8.10 | 11200 | 2.10 | EPA 3961290 → |
CAA**3721AM*+ furnace: 935CB66100C21***AHRI reference: 215648197 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961307 → |
CAA**3721AM*+ furnace: 987MC42060C17***AHRI reference: 215648218 | 17.50 | 8.10 | 11200 | 2.10 | EPA 3961322 → |
CAA**3721AM*+ furnace: 987MC60060C21***AHRI reference: 215648239 | 17.50 | 8.50 | 11200 | 2.10 | EPA 3961335 → |
CAA**3721AM*+ furnace: 987MC42080C17***AHRI reference: 215648259 | 17.50 | 8.10 | 11200 | 2.08 | EPA 3961353 → |
CAA**3721AM*+ furnace: 987MC60080C21***AHRI reference: 215648279 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961364 → |
CAA**3721AM*+ furnace: 987MC66100C21***AHRI reference: 215648300 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961377 → |
CAA**3721AM*+ furnace: 926SB48080V17***AHRI reference: 215648359 | 17.50 | 8.10 | 11200 | 2.08 | EPA 3961418 → |
CAA**3721AM*+ furnace: 935SB36040M17***AHRI reference: 215648417 | 17.50 | 8.10 | 11200 | 2.08 | EPA 3961458 → |
CAA**3721AM*+ furnace: 935SB48060M17***AHRI reference: 215648445 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961473 → |
CAA**3721AM*+ furnace: 935SB60080M21***AHRI reference: 215648469 | 17.50 | 8.10 | 11100 | 2.10 | EPA 3961494 → |
CAA**3721AM*+ furnace: 986TD42060C17***AHRI reference: 215648539 | 17.50 | 8.10 | 11200 | 2.10 | EPA 3961651 → |
CAA**3721AM*+ furnace: 926TC48080V17***AHRI reference: 215648673 | 17.50 | 8.10 | 11200 | 2.08 | EPA 3961680 → |
CAA**3721AM*+ furnace: OVMAAB036098AHRI reference: 215648785 | 17.50 | 8.10 | 11500 | 2.06 | EPA 3961757 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.