BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

PH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 10

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for PH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3017AM*+ furnace: 82*SB48070V17***AHRI reference: 21564544617.008.10110002.06EPA 3958470
CAA**3017AM*+ furnace: 82*SB48090V17***AHRI reference: 21564546717.008.10110002.04EPA 3958489
CAA**3017AM*+ furnace: 83*SB36040M17***AHRI reference: 21564548717.007.80108002.06EPA 3958500
CAA**3017AM*+ furnace: 88*TB36070C14***AHRI reference: 21564556317.008.10109002.06EPA 3958586
CAA**3017AM*+ furnace: 926TC48080V17***AHRI reference: 21564608817.008.10110002.06EPA 3958637
CAA**3017AM*+ furnace: 88*TB48070C17***AHRI reference: 21564558417.008.10109002.06EPA 3958659
CAA**3017AM*+ furnace: 88*TB48090C17***AHRI reference: 21564560517.008.10109002.06EPA 3958680
CAA**3017AM*+ furnace: 82*TB36045V14***AHRI reference: 21564562417.008.10109002.06EPA 3958697
CAA**3017AM*+ furnace: 82*TB36070V14***AHRI reference: 21564564917.008.10109002.06EPA 3958713
CAA**3017AM*+ furnace: 82*TB48070V17***AHRI reference: 21564566317.008.10110002.06EPA 3958721
CAA**3017AM*+ furnace: 82*TB48090V17***AHRI reference: 21564568517.008.10110002.04EPA 3958736
CAA**3017AM*+ furnace: 935CB48060C17***AHRI reference: 21564570017.007.80110002.06EPA 3958740
CAA**3017AM*+ furnace: 987MC42080C17***AHRI reference: 21564574417.008.10110002.06EPA 3958766
CAA**3017AM*+ furnace: 926SB48080V17***AHRI reference: 21564583817.008.10110002.06EPA 3958845
CAA**3017AM*+ furnace: 935SB48060M17***AHRI reference: 21564588417.007.80110002.04EPA 3958868
CAA**3017AM*+ furnace: OVMAAB042112AHRI reference: 21564615317.008.10112002.02EPA 3958900
CAA**3617AM*+ furnace: 83*CA36040C17***AHRI reference: 21564617417.007.80110002.06EPA 3958919
CAA**3017AM*+ furnace: 986TD42060C17***AHRI reference: 21564593417.008.10110002.06EPA 3958957
CAA**3017AM*+ furnace: 986TD42080C17***AHRI reference: 21564595617.008.10110002.06EPA 3958975
CAA**3617AM*+ furnace: 82*SB48090V17***AHRI reference: 21564625417.008.10109002.08EPA 3959042

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.