PH5SAN531**AA*
15 SEER2 HP
39 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for PH5SAN531**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 39 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 39 / 39 |
| EER2 · BTU/Wh | 11.7–13 | 39 / 39 |
| HSPF2 · BTU/Wh | 7.8–8 | 39 / 39 |
| Cooling capacity · BTU/h | 27,600–29,400 | 39 / 39 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,400–30,600 | 39 / 39 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–18,200 | 39 / 39 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,400–14,000 | 39 / 39 |
| COP at 5°F / −15°C | 2–2.06 | 39 / 39 |
| Equipment / loop type | HP - Split System | 39 / 39 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 39 / 39 |
| Compressor staging | Single stage | 39 / 39 |
| Connected capability | No | 39 / 39 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FJ5AN*C42L*AHRI reference: 217683350 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4505948 → |
PF5MN*C42L*AHRI reference: 217683351 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4505949 → |
F55AA*C42L*AHRI reference: 217683352 | 16.00 | 8.00 | 13400 | 2.05 | EPA 4505950 → |
FMA5X30**AL*AHRI reference: 217683597 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506049 → |
FM(C,U)5Z36**AL*AHRI reference: 217683501 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506113 → |
FM(C,U)5Z30**AL*AHRI reference: 217683469 | 16.00 | 8.00 | 13400 | 2.00 | EPA 4506686 → |
FMA5X36**AL*AHRI reference: 217683629 | 16.00 | 8.00 | 13700 | 2.00 | EPA 4506735 → |
CAA**3721AM*+ furnace: 935SB66100M21***AHRI reference: 217680776 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505597 → |
PF5MN*B30L*AHRI reference: 217679934 | 15.50 | 7.80 | 13400 | 2.00 | EPA 4505603 → |
CAA**3721AM*+ furnace: 83*SB48060M17***AHRI reference: 217680586 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505607 → |
CAA**3721AM*+ furnace: 83*SB60080M21***AHRI reference: 217680591 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4505637 → |
CAA**3721AM*+ furnace: 926TC66100V21***AHRI reference: 217680839 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505642 → |
CAA**3721AM*+ furnace: 927TA66100V21***AHRI reference: 217680864 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505648 → |
CAA**4321AM*+ furnace: 83*CB36040C17***AHRI reference: 217680924 | 15.50 | 8.00 | 13900 | 2.06 | EPA 4505675 → |
CAA**4321AM*+ furnace: 83*CB60080C21***AHRI reference: 217680934 | 15.50 | 8.00 | 13900 | 2.04 | EPA 4505680 → |
CAA**4321AM*+ furnace: 8(0,1)*SB60090M21***AHRI reference: 217680974 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505885 → |
CAA**4321AM*+ furnace: 8(0,1)*SB60110M21***AHRI reference: 217680979 | 15.50 | 8.00 | 14000 | 2.04 | EPA 4505917 → |
CAA**4321AM*+ furnace: 82*SB66110V21***AHRI reference: 217680999 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505922 → |
CAA**4321AM*+ furnace: 83*SB48060M17***AHRI reference: 217681009 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505927 → |
CAA**4321AM*+ furnace: 83*SB60080M21***AHRI reference: 217681014 | 15.50 | 8.00 | 14000 | 2.06 | EPA 4505932 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →