BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 7

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for GH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6121XMA*+ furnace: 83*CB60100C21***AHRI reference: 21572232417.008.00252002.24EPA 3982537
CVAVA6121XMA*+ furnace: 987TA66100C21***AHRI reference: 21572235217.008.00254002.10EPA 3982558
CVAVA6121XMA*+ furnace: 927TA60080V21***AHRI reference: 21572236617.008.00250002.10EPA 3982572
CVAVA6121XMA*+ furnace: 927TA60100V21***AHRI reference: 21572238217.008.00250002.12EPA 3982588
CVAVA6124XMA*+ furnace: 987TA66100C21***AHRI reference: 21572245517.008.00252002.12EPA 3982668
CVAVA6124XMA*+ furnace: 987TA66120C24***AHRI reference: 21572246917.008.00252002.12EPA 3982673
CVAVA6124XMA*+ furnace: 927TA60080V21***AHRI reference: 21572248317.008.00256002.10EPA 3982695
CVAVA6124XMA*+ furnace: 927TA60100V21***AHRI reference: 21572249917.008.00252002.12EPA 3982712
CVAMA4821XMA*+ furnace: 82*SB60090V21***AHRI reference: 21562290916.508.10244002.12EPA 3947314
CVAMA4821XMA*+ furnace: 82*SB66110V21***AHRI reference: 21562292216.508.10244002.14EPA 3947324
CVAMA4821XMA*+ furnace: 83*SB48060M17***AHRI reference: 21562293516.508.10246002.12EPA 3947337
CVAMA4821XMA*+ furnace: 83*SB60100M21***AHRI reference: 21562297316.508.10246002.12EPA 3947376
CVAMA4821XMA*+ furnace: 88*TB60090C21***AHRI reference: 21562300616.508.10244002.14EPA 3947412
CVAMA4821XMA*+ furnace: 88*TB60110C21***AHRI reference: 21562302016.508.10244002.12EPA 3947426
CVAMA4821XMA*+ furnace: 82*TB60090V21***AHRI reference: 21562303416.508.10244002.12EPA 3947439
CVAMA4821XMA*+ furnace: 82*TB66110V21***AHRI reference: 21562305016.508.10244002.14EPA 3947454
CVAMA4821XMA*+ furnace: 935SB60100M21***AHRI reference: 21562315616.508.10244002.12EPA 3947500
CVAMA4821XMA*+ furnace: 935SB66100M21***AHRI reference: 21562317516.508.10246002.12EPA 3947519
CVAMA4821XMA*+ furnace: 926TC66100V21***AHRI reference: 21562325316.508.10242002.12EPA 3947576
CVAMA4921XMA*+ furnace: 88*TB60070C21***AHRI reference: 21562334916.508.10256002.08EPA 3947673

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.