BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 19

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for GH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*6012AM*+ furnace: 83*CB60080C21***AHRI reference: 21571784116.007.80250002.20EPA 4001001
CAA**4821AM*+ furnace: 83*CA60080C21***AHRI reference: 21563120615.508.10252002.22EPA 3951988
CAA**4821AM*+ furnace: 82*SB60090V21***AHRI reference: 21563124715.508.10250002.20EPA 3952003
CAA**4821AM*+ furnace: 88*TB60070C21***AHRI reference: 21563135815.508.10254002.20EPA 3952204
CAA**4821AM*+ furnace: 82*TB60090V21***AHRI reference: 21563141615.508.10250002.20EPA 3952315
CAA**4821AM*+ furnace: 935CB60080C21***AHRI reference: 21563146415.508.10254002.20EPA 3952351
CAA**4821AM*+ furnace: 987MC60080C21***AHRI reference: 21563152015.508.10252002.22EPA 3952378
CAA**4821AM*+ furnace: 987MC66100C21***AHRI reference: 21563153415.508.10252002.20EPA 3952390
CAA**4821AM*+ furnace: 926SB60080V21***AHRI reference: 21563157415.508.10252002.22EPA 3952406
CAA**4821AM*+ furnace: 935SB60080M21***AHRI reference: 21563161915.508.10252002.20EPA 3952419
CAA**4821AM*+ furnace: 986TD66100C21***AHRI reference: 21563168515.508.10252002.20EPA 3952484
CAA**4821AM*+ furnace: 926TC60100V21***AHRI reference: 21563175715.508.10252002.20EPA 3952502
CAA**6024AM*+ furnace: 987MC66100C21***AHRI reference: 21563204715.508.10264002.16EPA 3952632
CAA**6024AM*+ furnace: 926SB60080V21***AHRI reference: 21563207515.508.10260002.18EPA 3952668
CAA**6024AM*+ furnace: 926SB60100V21***AHRI reference: 21563208815.508.10260002.18EPA 3952681
CAA**6024AM*+ furnace: 926SB66120V24***AHRI reference: 21563210115.508.10258002.20EPA 3952693
CAA**6024AM*+ furnace: 935SB60100M21***AHRI reference: 21563213315.508.10260002.20EPA 3952724
CAA**6121AM*+ furnace: 88*TB48070C17***AHRI reference: 21563244115.508.10262002.16EPA 3952738
CAA**6121AM*+ furnace: 82*TB48070V17***AHRI reference: 21563249715.508.10260002.18EPA 3952793
CAA**6024AM*+ furnace: 986TD66100C21***AHRI reference: 21563218015.508.10264002.16EPA 3952841

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →