BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 16

417 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for GH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 417 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18417 / 417
EER2 · BTU/Wh11.7–13.5417 / 417
HSPF2 · BTU/Wh7.8–8.5417 / 417
Cooling capacity · BTU/h45,500–50,500417 / 417
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500417 / 417
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600417 / 417
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600417 / 417
COP at 5°F / −15°C2.06–2.32417 / 417
Equipment / loop typeHP - Split System417 / 417
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)417 / 417
Compressor stagingTwo-stage417 / 417
Connected capabilityNo417 / 417

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6124AM*+ furnace: 926TC66120V24***AHRI reference: 21563323516.008.10266002.16EPA 3953359 →
CAA**6124AM*+ furnace: OVLAAB060154AHRI reference: 21563325116.008.10260002.20EPA 3953375 →
CAA**6124AM*+ furnace: 83*SB60100M21***AHRI reference: 21563285016.008.10262002.18EPA 3953406 →
CAA**6124AM*+ furnace: 88*TB60090C21***AHRI reference: 21563288316.008.10258002.20EPA 3953424 →
CAA**6124AM*+ furnace: 88*TB60110C21***AHRI reference: 21563289716.008.10264002.18EPA 3953437 →
CAA**6124AM*+ furnace: 88*TB66135C24***AHRI reference: 21563291116.008.10262002.18EPA 3953450 →
CAA**6124AM*+ furnace: 82*TB60090V21***AHRI reference: 21563292516.008.10260002.20EPA 3953466 →
CAA**6124AM*+ furnace: 82*TB66110V21***AHRI reference: 21563294116.008.10258002.20EPA 3953480 →
CAA**6124AM*+ furnace: 82*TB66135V24***AHRI reference: 21563295916.008.10260002.20EPA 3953501 →
CAA**6124AM*+ furnace: 935CB66100C21***AHRI reference: 21563298116.008.10260002.20EPA 3953508 →
CAA**6124AM*+ furnace: 935SB66100M21***AHRI reference: 21563312816.008.10262002.20EPA 3953521 →
CAA**6124AM*+ furnace: 986TD60080C21***AHRI reference: 21563314216.008.10264002.16EPA 3953535 →
CAA**6124AM*+ furnace: 986TD66100C21***AHRI reference: 21563315616.008.10266002.16EPA 3953551 →
CAA**6124AM*+ furnace: 987MC66100C21***AHRI reference: 21563302316.008.10266002.16EPA 3953594 →
CAA**6124AM*+ furnace: 926SB66120V24***AHRI reference: 21563307716.008.10262002.20EPA 3953634 →
CAA**6124AM*+ furnace: 935SB60100M21***AHRI reference: 21563310916.008.10260002.20EPA 3953647 →
CSAH*4812AM*+ furnace: 82*TB66110V21***AHRI reference: 21563354616.008.00250002.20EPA 3953681 →
CSAH*4812AM*+ furnace: 82*TB66135V24***AHRI reference: 21563356416.008.00248002.20EPA 3953699 →
CSAH*4812AM*+ furnace: 82*SB60090V21***AHRI reference: 21563333416.008.00250002.20EPA 3953762 →
CSAH*4812AM*+ furnace: 82*SB66110V21***AHRI reference: 21563334716.008.00250002.20EPA 3953776 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →