BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN536**AA*

2-STAGE 18 SEER HP · source records, page 13

274 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 274 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17274 / 274
EER2 · BTU/Wh11.7–13274 / 274
HSPF2 · BTU/Wh7.8–8.5274 / 274
Cooling capacity · BTU/h33,800–38,000274 / 274
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000274 / 274
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200274 / 274
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600274 / 274
COP at 5°F / −15°C1.78–2.48274 / 274
Equipment / loop typeHP - Split System274 / 274
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)274 / 274
Compressor stagingTwo-stage274 / 274
Connected capabilityNo274 / 274

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3612AM*+ furnace: 83*SB60080M21***AHRI reference: 21564000915.207.80188002.26EPA 3956504
CSAH*3612AM*+ furnace: 926TC66100V21***AHRI reference: 21564067515.207.80190002.24EPA 3956524
CSAH*4212AM*+ furnace: 83*CA60080C21***AHRI reference: 21564078415.208.10192002.24EPA 3956537
CSAH*4212AM*+ furnace: 82*SB60090V21***AHRI reference: 21564089215.207.80191002.26EPA 3956552
CSAH*4812AM*+ furnace: 88*TB60110C21***AHRI reference: 21564235815.208.10191002.26EPA 3956575
CSAH*4812AM*+ furnace: 88*TB66135C24***AHRI reference: 21564238015.208.10190002.26EPA 3956583
CSAH*4812AM*+ furnace: 82*TB60090V21***AHRI reference: 21564243715.208.10192002.24EPA 3956601
CSAH*4812AM*+ furnace: 935CB66100C21***AHRI reference: 21564249315.208.10190002.26EPA 3956616
CSAH*4812AM*+ furnace: 82*TB66135V24***AHRI reference: 21564247115.208.10190002.26EPA 3956621
CSAH*4812AM*+ furnace: 987MC66100C21***AHRI reference: 21564254915.208.10191002.26EPA 3956634
CSAH*4812AM*+ furnace: 926SB66120V24***AHRI reference: 21564264215.207.80190002.26EPA 3956652
CSAH*4812AM*+ furnace: 935SB60080M21***AHRI reference: 21564269315.207.80192002.26EPA 3956669
CSAH*4812AM*+ furnace: 935SB66100M21***AHRI reference: 21564274915.208.10190002.26EPA 3956681
CSAH*4212AM*+ furnace: 82*SB66110V21***AHRI reference: 21564091115.207.80190002.26EPA 3956699
CSAH*4212AM*+ furnace: 83*SB48060M17***AHRI reference: 21564098015.207.80190002.26EPA 3956711
CSAH*4212AM*+ furnace: 82*TB60090V21***AHRI reference: 21564130215.207.80191002.26EPA 3956744
CSAH*4812AM*+ furnace: 986TD66100C21***AHRI reference: 21564281115.208.10191002.26EPA 3956767
CSAH*4812AM*+ furnace: 926TC60100V21***AHRI reference: 21564291115.208.10191002.26EPA 3956792
CSAH*4812AM*+ furnace: 926TC66100V21***AHRI reference: 21564293815.208.10191002.26EPA 3956810
CSAH*4812AM*+ furnace: 926TC66120V24***AHRI reference: 21564296015.208.10193002.24EPA 3956829

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.