BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 8

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: 926TC48080V17***AHRI reference: 21564867217.508.10112002.08EPA 3961676
CAA**3721AM*+ furnace: OVMAAB036098AHRI reference: 21564878317.508.10115002.06EPA 3961756
CAA**3721AM*+ furnace: OVMAAB042112AHRI reference: 21564880417.508.10115002.18EPA 3961764
CAA**2517AM*+ furnace: 927TA48060V17***AHRI reference: 21572046817.508.00112002.08EPA 3980214
CAA**2517AM*+ furnace: 83*CB48060C17***AHRI reference: 21572042617.508.00110002.10EPA 3980248
CAA**2517AM*+ furnace: 927TA48080V17***AHRI reference: 21572048617.508.00111002.08EPA 3980294
CAA**3721AM*+ furnace: 83*CB60080C21***AHRI reference: 21572080817.508.00110002.12EPA 3981374
CAA**3721AM*+ furnace: 987TA60080C21***AHRI reference: 21572086417.508.00112002.10EPA 3981546
CAA**3721AM*+ furnace: 987TA66100C21***AHRI reference: 21572087817.508.00111002.10EPA 3981561
CAA**3721AM*+ furnace: 927TA48060V17***AHRI reference: 21572089217.508.00112002.10EPA 3981580
CAA**3721AM*+ furnace: 927TA48080V17***AHRI reference: 21572090817.508.00112002.08EPA 3981594
CAA**3721AM*+ furnace: 927TA60100V21***AHRI reference: 21572094017.508.00111002.10EPA 3981621
FT5ANXB24L*AHRI reference: 21556065817.508.10111002.06EPA 3982754
CVAVA3817XMA*+ furnace: 987MC42060C17***AHRI reference: 21561877717.508.00112002.10EPA 3996858
CAA**2517AM*+ furnace: 987TA48080C17***AHRI reference: 21710597817.508.00111002.08EPA 4001201
CAA**3717AM*+ furnace: 987TA48080C17***AHRI reference: 21710599617.508.00111002.08EPA 4001219
CAA**3721AM*+ furnace: 987TA48060C17***AHRI reference: 21710599917.508.00112002.08EPA 4001222
CAA**3721AM*+ furnace: 987TA48080C17***AHRI reference: 21710600217.508.00112002.10EPA 4001224
FT5BD2417X*AHRI reference: 21869535717.507.80112002.02EPA 4683473
CAA**2417AM*+ furnace: 83*CA36040C17***AHRI reference: 21564357617.007.80111002.04EPA 3957082

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →