BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 5

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2517AM*+ furnace: 987MC42080C17***AHRI reference: 21564472517.508.10111002.08EPA 3958006 →
CAA**2517AM*+ furnace: 926SB48060V17***AHRI reference: 21564480517.508.10112002.08EPA 3958075 →
CAA**2517AM*+ furnace: 926SB48080V17***AHRI reference: 21564482417.508.10111002.08EPA 3958091 →
CAA**2517AM*+ furnace: 935SB48060M17***AHRI reference: 21564487117.508.10111002.10EPA 3958122 →
CAA**2517AM*+ furnace: 986TD42060C17***AHRI reference: 21564492217.508.10111002.08EPA 3958158 →
CAA**2517AM*+ furnace: 986TD42080C17***AHRI reference: 21564494417.508.10111002.10EPA 3958162 →
CAA**2517AM*+ furnace: 926TC48060V17***AHRI reference: 21564504517.508.10112002.08EPA 3958233 →
CAA**2517AM*+ furnace: 926TC48080V17***AHRI reference: 21564507517.508.10111002.08EPA 3958255 →
CAA**2517AM*+ furnace: OVMAAB036098AHRI reference: 21564512117.508.10111002.10EPA 3958268 →
CAA**2517AM*+ furnace: OVMAAB042112AHRI reference: 21564514417.508.10115002.04EPA 3958288 →
CAA**3017AM*+ furnace: 83*SB48060M17***AHRI reference: 21564551317.507.80109002.08EPA 3958548 →
CAA**3617AM*+ furnace: 82*SB36045V14***AHRI reference: 21564619317.508.10109002.08EPA 3958925 →
CAA**3617AM*+ furnace: 82*SB36070V14***AHRI reference: 21564621417.508.10109002.08EPA 3959008 →
CAA**3617AM*+ furnace: 82*SB48070V17***AHRI reference: 21564623317.508.10110002.04EPA 3959028 →
CAA**3617AM*+ furnace: 83*SB36040M17***AHRI reference: 21564627017.507.80109002.06EPA 3959048 →
CAA**3617AM*+ furnace: 83*SB48060M17***AHRI reference: 21564629817.507.80109002.08EPA 3959070 →
CAA**3617AM*+ furnace: 82*TB36045V14***AHRI reference: 21564641017.508.10109002.08EPA 3959144 →
CAA**3617AM*+ furnace: 82*TB36070V14***AHRI reference: 21564643717.508.10109002.08EPA 3959166 →
CAA**3717AM*+ furnace: 82*SB48070V17***AHRI reference: 21564702017.508.10112002.08EPA 3959312 →
CAA**3717AM*+ furnace: 82*SB48090V17***AHRI reference: 21564703917.508.10110002.10EPA 3959327 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.