BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 26

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*2412AM*+ furnace: 82*SB60090V21***AHRI reference: 21564892216.008.00111002.05EPA 3997481 →
CSAH*2412AM*+ furnace: 82*SB48090V17***AHRI reference: 21564890216.008.00111002.05EPA 3997493 →
CSAH*3012AM*+ furnace: 987MC42060C17***AHRI reference: 21565091216.008.00111002.05EPA 3997579 →
CSAH*3012AM*+ furnace: 935SB36040M17***AHRI reference: 21565119216.008.00111002.05EPA 3997596 →
CSAH*3012AM*+ furnace: 926SB30040V14***AHRI reference: 21565103916.008.00113002.05EPA 3997615 →
CAA**3014AM*+ furnace: 986TD30040C14***AHRI reference: 21564530616.008.00111002.00EPA 3997627 →
CSAH*3012AM*+ furnace: 987TA48060C17***AHRI reference: 21710583716.008.00112002.05EPA 4001189 →
CSAH*3012AM*+ furnace: 987TA48080C17***AHRI reference: 21710600516.008.00111002.05EPA 4001228 →
CAA**3617AM*+ furnace: 987TA30040C14***AHRI reference: 21799192016.008.00113002.02EPA 4566267 →
CAA**3717AM*+ furnace: 987TA30040C14***AHRI reference: 21799193416.008.00113002.04EPA 4566281 →
CAA**3617AM*+ furnace: 927TA30040V14***AHRI reference: 21799175216.008.00112002.02EPA 4566329 →
CAA**2417AM*+ furnace: 927TA36060V14***AHRI reference: 21799136216.008.00111002.04EPA 4566468 →
CAA**2417AM*+ furnace: 927TA36040V17***AHRI reference: 21799150616.008.00113002.00EPA 4566533 →
CSAH*3012AM*+ furnace: 986TD60080C21***AHRI reference: 21565139015.507.80111002.06EPA 3719658 →
CAA**2517AM*+TDRAHRI reference: 21564308215.507.80111001.96EPA 3956914 →
CAA**3721AM*+TDRAHRI reference: 21564322015.507.80111001.94EPA 3956934 →
CAA**2414AM*+ furnace: 986TD30040C14***AHRI reference: 21564348615.507.80113002.00EPA 3957031 →
CAA**2414AM*+ furnace: 926TC30040V14***AHRI reference: 21564352515.508.10112002.02EPA 3957046 →
CAA**2417AM*+ furnace: 926SB30040V14***AHRI reference: 21564395015.507.80114002.00EPA 3957480 →
CAA**2417AM*+ furnace: 926TC30040V14***AHRI reference: 21564417115.507.80113001.98EPA 3957633 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →