BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 12

541 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 541 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5541 / 541
EER2 · BTU/Wh11.5–14541 / 541
HSPF2 · BTU/Wh7.8–8.5541 / 541
Cooling capacity · BTU/h22,200–25,000541 / 541
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400541 / 541
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000541 / 541
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500541 / 541
COP at 5°F / −15°C1.9–2.24541 / 541
Equipment / loop typeHP - Split System541 / 541
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)541 / 541
Compressor stagingTwo-stage541 / 541
Connected capabilityNo541 / 541

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 926TC48060V17***AHRI reference: 21564763117.008.10111002.08EPA 3960079
CAA**3717AM*+ furnace: OVLAAB036098AHRI reference: 21564768617.008.10111002.08EPA 3960111
CAA**3717AM*+ furnace: OVMAAB036098AHRI reference: 21564770817.008.10111002.08EPA 3960125
CAA**3717AM*+ furnace: OVMAAB042112AHRI reference: 21564772917.008.10115002.04EPA 3960139
CAA**3717AM*+ furnace: 926SB36060V14***AHRI reference: 21564737717.008.10111002.08EPA 3960187
CAA**3717AM*+ furnace: 926SB48060V17***AHRI reference: 21564739617.008.10111002.08EPA 3960331
CAA**3717AM*+ furnace: 935SB36040M17***AHRI reference: 21564743417.007.80111002.08EPA 3960356
CAA**3717AM*+ furnace: 935SB48060M17***AHRI reference: 21564746117.007.80110002.10EPA 3960379
CAA**3721AM*+ furnace: 926TC36040V17***AHRI reference: 21564861817.008.10114002.06EPA 3961081
CAA**3721AM*+ furnace: 926SB36040V17***AHRI reference: 21564831817.008.10114002.06EPA 3961387
CAA**3721AM*+ furnace: OVLAAB036098AHRI reference: 21564876317.008.10115002.04EPA 3961733
CSAH*3612AM*+ furnace: 88*TB36070C14***AHRI reference: 21565204417.007.80110002.08EPA 3964058
CSAH*3612AM*+ furnace: 82*TB66110V21***AHRI reference: 21565229417.007.80111002.08EPA 3964170
CSAH*3612AM*+ furnace: 83*CA36040C17***AHRI reference: 21565175417.008.10111002.08EPA 3964489
CSAH*3612AM*+ furnace: 82*SB66110V21***AHRI reference: 21565187217.007.80110002.08EPA 3964645
CSAH*3612AM*+ furnace: 83*SB60080M21***AHRI reference: 21565196717.007.80110002.10EPA 3964738
CSAH*3612AM*+ furnace: 935SB66100M21***AHRI reference: 21565278417.007.80110002.08EPA 3965074
CSAH*3612AM*+ furnace: 926TC66100V21***AHRI reference: 21565311817.007.80109002.10EPA 3965194
CSAH*3612AM*+ furnace: 926SB66120V24***AHRI reference: 21565265417.008.00110002.08EPA 3965601
CSAH*3612AM*+ furnace: 935SB60100M21***AHRI reference: 21565275717.007.80110002.08EPA 3965640

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →