BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH5SAN531**AA*

15 SEER2 HP · source records, page 2

41 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity27,400–29,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN531**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 41 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1641 / 41
EER2 · BTU/Wh11.7–1341 / 41
HSPF2 · BTU/Wh7.8–841 / 41
Cooling capacity · BTU/h27,400–29,40041 / 41
Heating capacity at 47°F / 8.3°C · BTU/h29,400–30,60041 / 41
Heating capacity at 17°F / −8.3°C · BTU/h17,500–18,20041 / 41
Heating capacity at 5°F / −15°C · BTU/h13,400–14,00041 / 41
COP at 5°F / −15°C2–2.0641 / 41
Equipment / loop typeHP - Split System41 / 41
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)41 / 41
Compressor stagingSingle stage41 / 41
Connected capabilityNo41 / 41

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FEVB0036**+NAVA53601CKAHRI reference: 21768321115.507.80134002.00EPA 4505968
PF5MN*B30L*AHRI reference: 21768322215.507.80134002.00EPA 4506021
F55AA*B30L*AHRI reference: 21768322315.507.80134002.00EPA 4506022
CAA**4321AM*+ furnace: 935SB66100M21***AHRI reference: 21768119815.508.00140002.06EPA 4506187
CAA**4321AM*+ furnace: 926TC66100V21***AHRI reference: 21768126615.508.00140002.06EPA 4506419
CAA**4321AM*+ furnace: 927TA66100V21***AHRI reference: 21768129115.508.00140002.06EPA 4506424
CAA**3721AM*+ furnace: 83*CB36040C17***AHRI reference: 21768050515.508.00139002.06EPA 4506492
CAA**3721AM*+ furnace: 83*CB60080C21***AHRI reference: 21768051515.508.00140002.06EPA 4506580
CAA**3721AM*+ furnace: 8(0,1)*SB60090M21***AHRI reference: 21768055015.508.00140002.06EPA 4506585
CAA**3721AM*+ furnace: 8(0,1)*SB60110M21***AHRI reference: 21768055515.508.00140002.06EPA 4506590
CAA**3721AM*+ furnace: 82*SB66110V21***AHRI reference: 21768057515.508.00140002.06EPA 4506595
CAA**3721AM*+ furnace: 83*SB48060M17***AHRI reference: 21768058515.508.00140002.06EPA 4506600
CAA**3721AM*+ furnace: 912SE60080M21***AHRI reference: 21768070015.508.00140002.06EPA 4506653
CAA**3721AM*+ furnace: 912SE60100M21***AHRI reference: 21768070515.508.00140002.06EPA 4506659
CAA**3721AM*+ furnace: 912SE66100M21***AHRI reference: 21768071015.508.00140002.06EPA 4506663
CAA**4321AM*+ furnace: 912SE60080M21***AHRI reference: 21768112315.508.00140002.06EPA 4506668
CAA**4321AM*+ furnace: 912SE60100M21***AHRI reference: 21768112815.508.00140002.06EPA 4506673
CAA**4321AM*+ furnace: 912SE66100M21***AHRI reference: 21768113315.508.00140002.06EPA 4506679
FM(C,U)5S36**AL*AHRI reference: 21845249215.508.00135002.00EPA 4624317
FM(C,U)5S30**AL*AHRI reference: 21845247315.508.00135002.00EPA 4624336

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →