BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP · source records, page 7

199 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5199 / 199
EER2 · BTU/Wh11.7–13199 / 199
HSPF2 · BTU/Wh7.8–8.5199 / 199
Cooling capacity · BTU/h22,200–24,400199 / 199
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000199 / 199
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200199 / 199
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900199 / 199
COP at 5°F / −15°C1.96–2.26199 / 199
Equipment / loop typeHP - Split System199 / 199
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)199 / 199
Compressor stagingSingle stage199 / 199
Connected capabilityNo199 / 199

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3117XMA*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21421315315.507.80113001.98EPA 3410208 →
CAA**3721AM*+ furnace: 83*SB36040M17***AHRI reference: 21421128615.507.80115002.16EPA 3410321 →
CAA**3721AM*+ furnace: 83*SB60080M21***AHRI reference: 21421134615.507.80114002.16EPA 3410576 →
CVAMA3217XMA*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 21421250815.507.80114002.00EPA 3411180 →
CVAMA3217XMA*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 21421247815.507.80114002.00EPA 3411269 →
CAA**3717AM*+ furnace: 83*SB48060M17***AHRI reference: 21421082415.507.80112002.10EPA 3411395 →
CVAMA3217XMA*+ furnace: 82*SB48070V17***AHRI reference: 21421262215.507.80113001.98EPA 3411890 →
FEVB0036**+NAVA53601CKAHRI reference: 21427755215.507.80114002.08EPA 3415798 →
FMA5X24**AL*AHRI reference: 21442404015.507.80108002.00EPA 3425323 →
FM(C,U)5Z24**AL*AHRI reference: 21582890015.508.00113002.10EPA 3713314 →
F55AA*B36L*AHRI reference: 21646379015.507.80114002.10EPA 3847029 →
FEVA0036**+NAVA53601CKAHRI reference: 21705151615.508.00113002.04EPA 4027332 →
FM(C,U)5S36**AL*AHRI reference: 21845230915.508.00112002.10EPA 4624436 →
FM(C,U)5S30**AL*AHRI reference: 21845227715.508.00112002.10EPA 4624468 →
CAA**2517AM*+ furnace: 926SB36060V14***AHRI reference: 21413093215.207.80115002.08EPA 3399845 →
CAA**2517AM*+ furnace: 916SA30026M14***AHRI reference: 21413084915.207.80116002.08EPA 3399963 →
CAA**2517AM*+ furnace: 916SA36060M14***AHRI reference: 21413087715.207.80116002.08EPA 3399971 →
CAA**3717AM*+ furnace: 916SA30026M14***AHRI reference: 21413290015.207.80115002.06EPA 3400025 →
CAA**3717AM*+ furnace: 916SA36060M14***AHRI reference: 21413292815.207.80116002.06EPA 3400053 →
CAA**3717AM*+ furnace: 926TC36060V14***AHRI reference: 21413310515.207.80115002.06EPA 3400090 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →