GH5SAN524**AA*
15 SEER2 HP · source records, page 7
199 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 199 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 199 / 199 |
| EER2 · BTU/Wh | 11.7–13 | 199 / 199 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 199 / 199 |
| Cooling capacity · BTU/h | 22,200–24,400 | 199 / 199 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,600–24,000 | 199 / 199 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 199 / 199 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,800–11,900 | 199 / 199 |
| COP at 5°F / −15°C | 1.96–2.26 | 199 / 199 |
| Equipment / loop type | HP - Split System | 199 / 199 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 199 / 199 |
| Compressor staging | Single stage | 199 / 199 |
| Connected capability | No | 199 / 199 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA3117XMA*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 214213153 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3410208 → |
CAA**3721AM*+ furnace: 83*SB36040M17***AHRI reference: 214211286 | 15.50 | 7.80 | 11500 | 2.16 | EPA 3410321 → |
CAA**3721AM*+ furnace: 83*SB60080M21***AHRI reference: 214211346 | 15.50 | 7.80 | 11400 | 2.16 | EPA 3410576 → |
CVAMA3217XMA*+ furnace: 8(0,1)*SB48070M17***AHRI reference: 214212508 | 15.50 | 7.80 | 11400 | 2.00 | EPA 3411180 → |
CVAMA3217XMA*+ furnace: 8(0,1)*SB36070M17***AHRI reference: 214212478 | 15.50 | 7.80 | 11400 | 2.00 | EPA 3411269 → |
CAA**3717AM*+ furnace: 83*SB48060M17***AHRI reference: 214210824 | 15.50 | 7.80 | 11200 | 2.10 | EPA 3411395 → |
CVAMA3217XMA*+ furnace: 82*SB48070V17***AHRI reference: 214212622 | 15.50 | 7.80 | 11300 | 1.98 | EPA 3411890 → |
FEVB0036**+NAVA53601CKAHRI reference: 214277552 | 15.50 | 7.80 | 11400 | 2.08 | EPA 3415798 → |
FMA5X24**AL*AHRI reference: 214424040 | 15.50 | 7.80 | 10800 | 2.00 | EPA 3425323 → |
FM(C,U)5Z24**AL*AHRI reference: 215828900 | 15.50 | 8.00 | 11300 | 2.10 | EPA 3713314 → |
F55AA*B36L*AHRI reference: 216463790 | 15.50 | 7.80 | 11400 | 2.10 | EPA 3847029 → |
FEVA0036**+NAVA53601CKAHRI reference: 217051516 | 15.50 | 8.00 | 11300 | 2.04 | EPA 4027332 → |
FM(C,U)5S36**AL*AHRI reference: 218452309 | 15.50 | 8.00 | 11200 | 2.10 | EPA 4624436 → |
FM(C,U)5S30**AL*AHRI reference: 218452277 | 15.50 | 8.00 | 11200 | 2.10 | EPA 4624468 → |
CAA**2517AM*+ furnace: 926SB36060V14***AHRI reference: 214130932 | 15.20 | 7.80 | 11500 | 2.08 | EPA 3399845 → |
CAA**2517AM*+ furnace: 916SA30026M14***AHRI reference: 214130849 | 15.20 | 7.80 | 11600 | 2.08 | EPA 3399963 → |
CAA**2517AM*+ furnace: 916SA36060M14***AHRI reference: 214130877 | 15.20 | 7.80 | 11600 | 2.08 | EPA 3399971 → |
CAA**3717AM*+ furnace: 916SA30026M14***AHRI reference: 214132900 | 15.20 | 7.80 | 11500 | 2.06 | EPA 3400025 → |
CAA**3717AM*+ furnace: 916SA36060M14***AHRI reference: 214132928 | 15.20 | 7.80 | 11600 | 2.06 | EPA 3400053 → |
CAA**3717AM*+ furnace: 926TC36060V14***AHRI reference: 214133105 | 15.20 | 7.80 | 11500 | 2.06 | EPA 3400090 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →