37MURAQ24AA3+KSAIC0701230
Crossover Heat Pump · Crossover heat pump · source records, page 7
140 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MURAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 140 / 140 |
| EER2 · BTU/Wh | 9.5–10 | 140 / 140 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 140 / 140 |
| Cooling capacity · BTU/h | 23,200–25,200 | 140 / 140 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–26,000 | 140 / 140 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,300–19,500 | 140 / 140 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,000–20,000 | 140 / 140 |
| COP at 5°F / −15°C | 1.88–2.14 | 140 / 140 |
| Equipment / loop type | HP - Split System | 140 / 140 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 140 / 140 |
| Compressor staging | Continuously variable | 140 / 140 |
| Connected capability | No | 140 / 140 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*3612AM*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 218481465 | 15.20 | 8.50 | 19300 | 1.94 | EPA 4628717 → |
CAA**3721AM*+ furnace: 82*SB60090V21***Cold climate designationAHRI reference: 218481458 | 15.20 | 8.50 | 19100 | 1.96 | EPA 4628720 → |
CAA**3017AM*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 218481451 | 15.20 | 8.50 | 19400 | 1.92 | EPA 4628723 → |
CAA**3017AM*+ furnace: 82*SB48070V17***Cold climate designationAHRI reference: 218481439 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4628726 → |
CSAH*3612AM*+ furnace: 82*SB36070V14***Cold climate designationAHRI reference: 218481434 | 15.20 | 8.50 | 19300 | 1.92 | EPA 4628727 → |
CAA**3014AM*+ furnace: 82*SB36070V14***Cold climate designationAHRI reference: 218481422 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4628731 → |
CAA**3017AM*+ furnace: 82*SB36045V14***Cold climate designationAHRI reference: 218481408 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4628734 → |
CSAH*3612AM*+ furnace: 8(0,1)*SB60110M24***Cold climate designationAHRI reference: 218481399 | 15.20 | 8.50 | 19300 | 1.94 | EPA 4628736 → |
CSAH*3612AM*+ furnace: 8(0,1)*SB48090M21***Cold climate designationAHRI reference: 218481385 | 15.20 | 8.50 | 19300 | 1.92 | EPA 4628740 → |
CAA**3617AM*+ furnace: 8(0,1)*SB42090M17***Cold climate designationAHRI reference: 218481361 | 15.20 | 8.50 | 19400 | 1.92 | EPA 4628746 → |
CAA**3017AM*+ furnace: 8(0,1)*SB42090M17***Cold climate designationAHRI reference: 218481357 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4628748 → |
CAA**3017AM*+ furnace: 8(0,1)*SB48070M17***Cold climate designationAHRI reference: 218481326 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4628754 → |
CAA**2417AM*+ furnace: 8(0,1)*SB36070M17***Cold climate designationAHRI reference: 218481304 | 15.20 | 9.00 | 19600 | 2.00 | EPA 4628758 → |
CSAH*3612AM*+ furnace: 8(0,1)*SB36070M14***Cold climate designationAHRI reference: 218481291 | 15.20 | 8.50 | 19200 | 1.94 | EPA 4628764 → |
CAA**2417AM*+ furnace: 8(0,1)*SB36070M14***Cold climate designationAHRI reference: 218481278 | 15.20 | 8.50 | 19600 | 1.90 | EPA 4628768 → |
CAA**2414AM*+ furnace: 8(0,1)*SB36070M14***Cold climate designationAHRI reference: 218481273 | 15.20 | 8.50 | 19600 | 1.88 | EPA 4628770 → |
CAA**3721AM*+ furnace: 8(0,1)*SB42045M17***Cold climate designationAHRI reference: 218481268 | 15.20 | 8.50 | 19000 | 1.96 | EPA 4628772 → |
CAA**2517AM*+ furnace: 8(0,1)*SB42045M17***Cold climate designationAHRI reference: 218481264 | 15.20 | 8.50 | 19100 | 1.96 | EPA 4628774 → |
CAA**3017AM*+ furnace: 8(0,1)*SB36045M14***Cold climate designationAHRI reference: 218481237 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4628776 → |
CAA**3014AM*+ furnace: 8(0,1)*SB36045M14***Cold climate designationAHRI reference: 218481233 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4628778 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →