BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

37MURAQ24AA3+KSAIC0701230

Crossover Heat Pump · Crossover heat pump

140 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,200–25,200BTU/h

Each efficiency range summarizes published EPA records for 37MURAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16140 / 140
EER2 · BTU/Wh9.5–10140 / 140
HSPF2 · BTU/Wh8.5–9.5140 / 140
Cooling capacity · BTU/h23,200–25,200140 / 140
Heating capacity at 47°F / 8.3°C · BTU/h24,000–26,000140 / 140
Heating capacity at 17°F / −8.3°C · BTU/h18,300–19,500140 / 140
Heating capacity at 5°F / −15°C · BTU/h19,000–20,000140 / 140
COP at 5°F / −15°C1.88–2.14140 / 140
Equipment / loop typeHP - Split System140 / 140
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)140 / 140
Compressor stagingContinuously variable140 / 140
Connected capabilityNo140 / 140

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X24**AL*Cold climate designationAHRI reference: 21848229316.009.00198001.98EPA 4628538 →
PF5TNXC36L*Cold climate designationAHRI reference: 21848228816.009.00194002.02EPA 4628540 →
FG5ANXC36L*Cold climate designationAHRI reference: 21848228616.009.00194002.02EPA 4628541 →
FT5AN(B,X)C36L*Cold climate designationAHRI reference: 21848228416.009.00194002.02EPA 4628542 →
FM(C,U)5Z36**AL*Cold climate designationAHRI reference: 21848226816.009.50196002.14EPA 4628550 →
FM(C,U)5Z30**AL*Cold climate designationAHRI reference: 21848226316.009.50196002.14EPA 4628552 →
CAA**3721AM*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 21848199316.009.00191002.06EPA 4628596 →
CSAH*3612AM*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 21848199016.008.50194001.92EPA 4628597 →
CAA**3721AM*+ furnace: 926SB60100V21***Cold climate designationAHRI reference: 21848192416.009.00191002.06EPA 4628612 →
CAA**3721AM*+ furnace: 912SE60100M21***Cold climate designationAHRI reference: 21848172716.008.50190001.96EPA 4628630 →
CAA**2517AM*+ furnace: 82*TB48090V17***Cold climate designationAHRI reference: 21848162716.009.00191002.06EPA 4628660 →
CAA**2517AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 21848149616.009.00192002.06EPA 4628703 →
CAA**3717AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 21848149216.009.00192002.06EPA 4628705 →
CAA**3721AM*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 21848147416.008.50190001.94EPA 4628713 →
CAA**2517AM*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 21848147016.008.50191001.94EPA 4628715 →
CAA**2517AM*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 21848145516.009.00191002.06EPA 4628721 →
CAA**2517AM*+ furnace: 8(0,1)*SB36070M14***Cold climate designationAHRI reference: 21848129516.008.50191001.96EPA 4628762 →
FT5ANXB24L*Cold climate designationAHRI reference: 21847537915.509.00195001.98EPA 4626412 →
FM(C,U)5Z24**AL*Cold climate designationAHRI reference: 21848224315.509.00198002.00EPA 4628556 →
CAA**3721AM*+ furnace: 927TA66100V21***Cold climate designationAHRI reference: 21848222215.509.00191002.08EPA 4628558 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →