Heating performance & equipment details
Ranges include the 355 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 355 / 355 |
| EER2 · BTU/Wh | 9.5–10.5 | 355 / 355 |
| HSPF2 · BTU/Wh | 8.1–9 | 355 / 355 |
| Cooling capacity · BTU/h | 28,600–31,200 | 355 / 355 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 355 / 355 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 355 / 355 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 355 / 355 |
| COP at 5°F / −15°C | 1.75–2 | 355 / 355 |
| Equipment / loop type | HP - Split System | 355 / 355 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 355 / 355 |
| Compressor staging | Continuously variable | 355 / 355 |
| Connected capability | No | 355 / 355 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**4221AM*+ furnace: 8(0,1)*SB48070M17***Cold climate designationAHRI reference: 218478400 | 15.50 | 8.50 | 32800 | 1.80 | EPA 4627393 → |
CAA**4221AM*+ furnace: 8(0,1)*SB36070M17***Cold climate designationAHRI reference: 218478396 | 15.50 | 8.50 | 32800 | 1.80 | EPA 4627395 → |
CAA**4321AM*+ furnace: OVLAAB048112Cold climate designationAHRI reference: 218478387 | 15.50 | 9.00 | 32200 | 2.00 | EPA 4627399 → |
CAA**4321AM*+ furnace: 926TC36040V17***Cold climate designationAHRI reference: 218478339 | 15.50 | 9.00 | 32400 | 1.96 | EPA 4627422 → |
CAA**4321AM*+ furnace: 926SB36040V17***Cold climate designationAHRI reference: 218478311 | 15.50 | 9.00 | 32400 | 1.96 | EPA 4627436 → |
CAA**4321AM*+ furnace: 916SA66100M21***Cold climate designationAHRI reference: 218478309 | 15.50 | 9.00 | 32200 | 1.98 | EPA 4627437 → |
CAA**4321AM*+ furnace: 916SA60080M21***Cold climate designationAHRI reference: 218478301 | 15.50 | 9.00 | 32200 | 1.96 | EPA 4627441 → |
CAA**4321AM*+ furnace: 916SA48080M17***Cold climate designationAHRI reference: 218478297 | 15.50 | 9.00 | 32200 | 1.98 | EPA 4627443 → |
CAA**4321AM*+ furnace: 8(0,1)*SB48070M17***Cold climate designationAHRI reference: 218478214 | 15.50 | 9.00 | 32200 | 1.98 | EPA 4627486 → |
CAA**4321AM*+ furnace: 8(0,1)*SB42045M17***Cold climate designationAHRI reference: 218478206 | 15.50 | 9.00 | 32200 | 1.96 | EPA 4627490 → |
CSAH*3012AM*+ furnace: 927TA66100V21***Cold climate designationAHRI reference: 218478197 | 15.50 | 8.50 | 33000 | 1.80 | EPA 4627491 → |
CSAH*3012AM*+ furnace: 926TC66100V21***Cold climate designationAHRI reference: 218478173 | 15.50 | 8.50 | 33000 | 1.80 | EPA 4627494 → |
CSAH*3012AM*+ furnace: 935SB66100M21***Cold climate designationAHRI reference: 218478147 | 15.50 | 8.50 | 33000 | 1.80 | EPA 4627498 → |
CSAH*3012AM*+ furnace: 935SB60100M21***Cold climate designationAHRI reference: 218478143 | 15.50 | 8.50 | 33000 | 1.78 | EPA 4627500 → |
CSAH*3012AM*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 218478049 | 15.50 | 8.50 | 33000 | 1.80 | EPA 4627511 → |
CSAH*3612AM*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 218477988 | 15.50 | 8.50 | 32600 | 1.84 | EPA 4627514 → |
CSAH*3612AM*+ furnace: 927TA60100V21***Cold climate designationAHRI reference: 218477975 | 15.50 | 8.50 | 32600 | 1.80 | EPA 4627519 → |
CSAH*3612AM*+ furnace: 926TC60100V21***Cold climate designationAHRI reference: 218477951 | 15.50 | 8.50 | 32600 | 1.80 | EPA 4627529 → |
CSAH*3612AM*+ furnace: 935SB60080M21***Cold climate designationAHRI reference: 218477917 | 15.50 | 8.50 | 32600 | 1.82 | EPA 4627540 → |
CSAH*3612AM*+ furnace: 926SB66120V24***Cold climate designationAHRI reference: 218477908 | 15.50 | 8.50 | 32600 | 1.80 | EPA 4627543 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →