37MUHAQ24AA3+KSAIC0701230
Crossover Heat Pump · source records, page 8
528 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 528 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 528 / 528 |
| EER2 · BTU/Wh | 10–11 | 528 / 528 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 528 / 528 |
| Cooling capacity · BTU/h | 22,600–25,000 | 528 / 528 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 528 / 528 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 528 / 528 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 528 / 528 |
| COP at 5°F / −15°C | 1.85–2.06 | 528 / 528 |
| Equipment / loop type | HP - Split System | 528 / 528 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 528 / 528 |
| Compressor staging | Continuously variable | 528 / 528 |
| Connected capability | No | 528 / 528 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3017AM*+ furnace: 926TC48060V17***Cold climate designationAHRI reference: 218476871 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4626569 → |
CAA**3017AM*+ furnace: 926TC36060V14***Cold climate designationAHRI reference: 218476869 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4626571 → |
CAA**3017AM*+ furnace: 935SB36040M17***Cold climate designationAHRI reference: 218476861 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4626579 → |
CAA**3017AM*+ furnace: 926SB48080V17***Cold climate designationAHRI reference: 218476860 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4626580 → |
CAA**3017AM*+ furnace: 926SB48060V17***Cold climate designationAHRI reference: 218476859 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4626581 → |
CAA**3017AM*+ furnace: 926SB36060V14***Cold climate designationAHRI reference: 218476858 | 16.50 | 8.50 | 19500 | 1.88 | EPA 4626582 → |
CAA**3014AM*+ furnace: 926TC36060V14***Cold climate designationAHRI reference: 218476838 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4626602 → |
CAA**3014AM*+ furnace: 926SB36060V14***Cold climate designationAHRI reference: 218476835 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4626605 → |
CAA**3014AM*+ furnace: 82*TB36045V14***Cold climate designationAHRI reference: 218476830 | 16.50 | 8.50 | 19400 | 1.88 | EPA 4626610 → |
CAA**3014AM*+ furnace: 82*SB36045V14***Cold climate designationAHRI reference: 218476828 | 16.50 | 8.50 | 19400 | 1.88 | EPA 4626612 → |
CAA**2517AM*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 218476827 | 16.50 | 9.00 | 19300 | 2.02 | EPA 4626613 → |
CAA**2517AM*+ furnace: 926TC36040V17***Cold climate designationAHRI reference: 218476813 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4626627 → |
CAA**2517AM*+ furnace: 926TC30040V14***Cold climate designationAHRI reference: 218476811 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4626629 → |
CAA**2517AM*+ furnace: 926SB36040V17***Cold climate designationAHRI reference: 218476803 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4626637 → |
CAA**2517AM*+ furnace: 926SB30040V14***Cold climate designationAHRI reference: 218476802 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4626638 → |
CAA**2417AM*+ furnace: 927TA48080V17***Cold climate designationAHRI reference: 218476781 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4626659 → |
CAA**2417AM*+ furnace: 927TA48060V17***Cold climate designationAHRI reference: 218476779 | 16.50 | 9.00 | 19800 | 1.98 | EPA 4626661 → |
CAA**2417AM*+ furnace: 926TC48080V17***Cold climate designationAHRI reference: 218476777 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4626663 → |
CAA**2417AM*+ furnace: 926TC48060V17***Cold climate designationAHRI reference: 218476775 | 16.50 | 9.00 | 19800 | 1.98 | EPA 4626665 → |
CAA**2417AM*+ furnace: 926TC36060V14***Cold climate designationAHRI reference: 218476773 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4626667 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →