37MUHAQ24AA3+KSAIC0701230
Crossover Heat Pump · source records, page 3
528 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 528 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 528 / 528 |
| EER2 · BTU/Wh | 10–11 | 528 / 528 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 528 / 528 |
| Cooling capacity · BTU/h | 22,600–25,000 | 528 / 528 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 528 / 528 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 528 / 528 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 528 / 528 |
| COP at 5°F / −15°C | 1.85–2.06 | 528 / 528 |
| Equipment / loop type | HP - Split System | 528 / 528 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 528 / 528 |
| Compressor staging | Continuously variable | 528 / 528 |
| Connected capability | No | 528 / 528 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3721AM*+ furnace: 926TC48060V17***Cold climate designationAHRI reference: 218477002 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4626438 → |
CAA**3721AM*+ furnace: 935SB60080M21***Cold climate designationAHRI reference: 218476995 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4626445 → |
CAA**3721AM*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 218476993 | 17.00 | 8.50 | 18800 | 1.90 | EPA 4626447 → |
CAA**3721AM*+ furnace: 935SB36040M17***Cold climate designationAHRI reference: 218476991 | 17.00 | 8.50 | 18900 | 1.90 | EPA 4626449 → |
CAA**3721AM*+ furnace: 926SB60100V21***Cold climate designationAHRI reference: 218476990 | 17.00 | 9.00 | 19000 | 2.02 | EPA 4626450 → |
CAA**3721AM*+ furnace: 926SB60080V21***Cold climate designationAHRI reference: 218476989 | 17.00 | 8.50 | 18900 | 1.92 | EPA 4626451 → |
CAA**3721AM*+ furnace: 926SB48080V17***Cold climate designationAHRI reference: 218476988 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4626452 → |
CAA**3721AM*+ furnace: 926SB48060V17***Cold climate designationAHRI reference: 218476987 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4626453 → |
CAA**3721AM*+ furnace: 82*TB48090V17***Cold climate designationAHRI reference: 218476980 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4626460 → |
CAA**3721AM*+ furnace: 82*TB48070V17***Cold climate designationAHRI reference: 218476978 | 17.00 | 8.50 | 18800 | 1.90 | EPA 4626462 → |
CAA**3721AM*+ furnace: 83*SB60100M21***Cold climate designationAHRI reference: 218476976 | 17.00 | 8.50 | 18900 | 1.92 | EPA 4626464 → |
CAA**3721AM*+ furnace: 83*SB60080M21***Cold climate designationAHRI reference: 218476974 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4626466 → |
CAA**3721AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 218476972 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4626468 → |
CAA**3721AM*+ furnace: 82*SB48090V17***Cold climate designationAHRI reference: 218476967 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4626473 → |
CAA**3721AM*+ furnace: 82*SB48070V17***Cold climate designationAHRI reference: 218476966 | 17.00 | 8.50 | 18800 | 1.90 | EPA 4626474 → |
CAA**3717AM*+ furnace: 927TA48080V17***Cold climate designationAHRI reference: 218476961 | 17.00 | 8.50 | 19200 | 1.92 | EPA 4626479 → |
CAA**3717AM*+ furnace: 927TA48060V17***Cold climate designationAHRI reference: 218476959 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4626481 → |
CAA**3717AM*+ furnace: 926TC48080V17***Cold climate designationAHRI reference: 218476957 | 17.00 | 8.50 | 19200 | 1.92 | EPA 4626483 → |
CAA**3717AM*+ furnace: 926TC48060V17***Cold climate designationAHRI reference: 218476955 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4626485 → |
CAA**3717AM*+ furnace: 935SB48060M17***Cold climate designationAHRI reference: 218476947 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4626493 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →