70 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity17,400–18,700BTU/h

Each efficiency range summarizes published EPA records for 37MUHAQ18AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 70 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.570 / 70
EER2 · BTU/Wh10–1170 / 70
HSPF2 · BTU/Wh8.1–970 / 70
Cooling capacity · BTU/h17,400–18,70070 / 70
Heating capacity at 47°F / 8.3°C · BTU/h18,900–20,20070 / 70
Heating capacity at 17°F / −8.3°C · BTU/h14,400–15,30070 / 70
Heating capacity at 5°F / −15°C · BTU/h16,300–17,60070 / 70
COP at 5°F / −15°C1.85–2.0470 / 70
Equipment / loop typeHP - Split System70 / 70
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)70 / 70
Compressor stagingContinuously variable70 / 70
Connected capabilityNo70 / 70

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2517AM*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 21847564315.508.10171001.90EPA 4626317
CAA**2517AM*+ furnace: 82*SB36070V14***Cold climate designationAHRI reference: 21847564115.508.10171001.90EPA 4626318
CAA**2517AM*+ furnace: 8(0,1)*SB48070M17***Cold climate designationAHRI reference: 21847563615.508.50163001.94EPA 4626323
CAA**2517AM*+ furnace: 8(0,1)*SB36070M17***Cold climate designationAHRI reference: 21847563415.508.50164001.94EPA 4626325
CAA**2517AM*+ furnace: 8(0,1)*SB36070M14***Cold climate designationAHRI reference: 21847563215.508.50164001.94EPA 4626327
CAA**2517AM*+ furnace: 8(0,1)*SB36045M14***Cold climate designationAHRI reference: 21847562815.508.50164001.94EPA 4626329
CAA**3017AM*+ furnace: OVLAAB036098Cold climate designationAHRI reference: 21847560215.508.10174001.90EPA 4626337
CAA**3017AM*+ furnace: 83*SB48060M17***Cold climate designationAHRI reference: 21847555415.508.10172001.90EPA 4626343
CAA**3017AM*+ furnace: 83*SB36040M17***Cold climate designationAHRI reference: 21847555215.508.10172001.90EPA 4626345
CAA**3017AM*+ furnace: 8(0,1)*SB36070M17***Cold climate designationAHRI reference: 21847554215.508.10165001.85EPA 4626349
CAA**3017AM*+ furnace: 8(0,1)*SB36070M14***Cold climate designationAHRI reference: 21847554015.508.10164001.85EPA 4626351
FM(C,U)5Z18**AL*Cold climate designationAHRI reference: 21847545415.509.00171002.04EPA 4626364
FM(C,U)5Z24**AL*Cold climate designationAHRI reference: 21847545215.509.00171002.04EPA 4626366
CAA**1917AM*+ furnace: 926TC36060V14***Cold climate designationAHRI reference: 21847583315.208.10170001.90EPA 4626253
CAA**1917AM*+ furnace: 926SB36060V14***Cold climate designationAHRI reference: 21847582215.208.10170001.90EPA 4626254
CAA**1917AM*+ furnace: 916SA48080M17***Cold climate designationAHRI reference: 21847581815.208.50166001.95EPA 4626256
CAA**1917AM*+ furnace: 916SA36060M14***Cold climate designationAHRI reference: 21847581415.208.10164001.85EPA 4626258
CAA**1917AM*+ furnace: 912SE42060M17***Cold climate designationAHRI reference: 21847580415.208.50165001.95EPA 4626262
CAA**1917AM*+ furnace: 912SE36060M14***Cold climate designationAHRI reference: 21847580215.208.10163001.85EPA 4626264
CAA**1917AM*+ furnace: 8(0,1)*SB42090M17***Cold climate designationAHRI reference: 21847578615.208.50165001.95EPA 4626270