293VAN048**AA*
Evolution 23 VS Heat Pump · source records, page 2
78 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN048**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 20–23 | 78 / 78 |
| EER2 · BTU/Wh | 10–12.5 | 78 / 78 |
| HSPF2 · BTU/Wh | 9–9.5 | 78 / 78 |
| Cooling capacity · BTU/h | 43,000–46,500 | 78 / 78 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,000–48,500 | 63 / 78 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 39,000–40,500 | 78 / 78 |
| Heating capacity at 5°F / −15°C · BTU/h | 35,600–37,400 | 78 / 78 |
| COP at 5°F / −15°C | 1.8–2 | 78 / 78 |
| Equipment / loop type | HP - Split System | 78 / 78 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 78 / 78 |
| Compressor staging | Continuously variable | 78 / 78 |
| Connected capability | No | 78 / 78 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**6121AM*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215934215 | 21.00 | 9.00 | 37000 | 1.86 | EPA 3726254 → |
CAA**6121AM*+UI+ furnace: 986TD66100C21***Cold climate designationAHRI reference: 215934285 | 21.00 | 9.00 | 36800 | 1.88 | EPA 3726932 → |
CAA**6121AM*+UI+ furnace: 987MC66100C21***Cold climate designationAHRI reference: 215934265 | 21.00 | 9.50 | 36800 | 2.00 | EPA 3726963 → |
CAA**6124AM*+UI+ furnace: 83*CA60100C21***Cold climate designationAHRI reference: 215934295 | 21.00 | 9.50 | 36800 | 2.00 | EPA 3727529 → |
CAA**4821AM*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215934035 | 21.00 | 9.00 | 36200 | 1.88 | EPA 3728292 → |
CAA**4821AM*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215934005 | 21.00 | 9.00 | 36200 | 1.88 | EPA 3730131 → |
CAA**4821AM*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215934015 | 21.00 | 9.00 | 36400 | 1.88 | EPA 3730141 → |
CAA**6024AM*+UI+ furnace: 83*CA60100C21***Cold climate designationAHRI reference: 215934085 | 21.00 | 9.50 | 36400 | 2.00 | EPA 3732329 → |
CAA**6024AM*+UI+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 215934095 | 21.00 | 9.00 | 36600 | 1.88 | EPA 3732341 → |
CAA**6024AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215940995 | 21.00 | 9.00 | 36600 | 1.90 | EPA 3734326 → |
CAA**6024AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215941005 | 21.00 | 9.00 | 36600 | 1.90 | EPA 3734335 → |
CAA**6024AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215941015 | 21.00 | 9.00 | 36400 | 1.90 | EPA 3734345 → |
CAA**6024AM*+UI+ furnace: 987TA66120C24***Cold climate designationAHRI reference: 215941025 | 21.00 | 9.00 | 36400 | 1.88 | EPA 3734355 → |
CAA**6121AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215941035 | 21.00 | 9.00 | 37000 | 1.86 | EPA 3734365 → |
CAA**6121AM*+UI+ furnace: 83*CB48060C17***Cold climate designationAHRI reference: 215941055 | 21.00 | 9.00 | 37000 | 1.86 | EPA 3735536 → |
CAA**6121AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215941075 | 21.00 | 9.00 | 37000 | 1.86 | EPA 3735556 → |
CAA**6121AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215941085 | 21.00 | 9.00 | 36800 | 1.88 | EPA 3735566 → |
CAA**6124AM*+UI+ furnace: 986TD60080C21***Cold climate designationAHRI reference: 215941095 | 21.00 | 9.00 | 37000 | 1.88 | EPA 3735576 → |
CAA**6124AM*+UI+ furnace: 987TA60080C21***Cold climate designationAHRI reference: 215941105 | 21.00 | 9.00 | 37000 | 1.88 | EPA 3735586 → |
CAA**4821AM*+UI+ furnace: 987TA66100C21***Cold climate designationAHRI reference: 215940985 | 21.00 | 9.00 | 36400 | 1.88 | EPA 3735981 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.