293VAN036**AA*
Evolution 23 VS Heat Pump · source records, page 7
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 293VAN036**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,800–39,500 | 371 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.1 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA4921XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 215935095 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3724523 → |
CVAMA4921XMA*+UI+ furnace: 987MC60080C21***Cold climate designationAHRI reference: 215935105 | 21.50 | 8.50 | 28600 | 2.04 | EPA 3724533 → |
CVAMA4921XMA*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 215935125 | 21.50 | 8.50 | 28800 | 2.02 | EPA 3724553 → |
CVAVA6024XMA*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215936785 | 21.50 | 8.50 | 28600 | 2.04 | EPA 3724729 → |
FE5BN(B,X)C48L*+UICold climate designationAHRI reference: 215931496 | 21.50 | 9.50 | 25800 | 2.06 | EPA 3725116 → |
CVAVA6121XMA*+UI+ furnace: 987MC60060C21***Cold climate designationAHRI reference: 215936895 | 21.50 | 8.50 | 28600 | 2.00 | EPA 3725195 → |
CVAVA6121XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 215936905 | 21.50 | 8.50 | 28800 | 2.06 | EPA 3725205 → |
CVAVA6121XMA*+UI+ furnace: 986TD42060C17***Cold climate designationAHRI reference: 215936915 | 21.50 | 8.50 | 28200 | 2.06 | EPA 3725273 → |
CVAMA4421XMA*+UI+ furnace: 83*CA60100C21***Cold climate designationAHRI reference: 215934795 | 21.50 | 8.50 | 28800 | 2.02 | EPA 3725281 → |
CVAMA4421XMA*+UI+ furnace: 88*TB48070C17***Cold climate designationAHRI reference: 215934815 | 21.50 | 8.50 | 29000 | 2.04 | EPA 3725301 → |
CVAMA4421XMA*+UI+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 215934825 | 21.50 | 8.50 | 28600 | 2.02 | EPA 3725311 → |
CVAVA4824XMA*+UI+ furnace: 88*TB60090C21***Cold climate designationAHRI reference: 215936315 | 21.50 | 8.50 | 28200 | 2.06 | EPA 3725345 → |
CVAVA4824XMA*+UI+ furnace: 88*TB60110C21***Cold climate designationAHRI reference: 215936325 | 21.50 | 8.50 | 28200 | 2.06 | EPA 3725355 → |
CVAVA4824XMA*+UI+ furnace: 88*TB66135C24***Cold climate designationAHRI reference: 215936335 | 21.50 | 8.50 | 28200 | 2.06 | EPA 3725365 → |
CVAVA4824XMA*+UI+ furnace: 935CB66100C21***Cold climate designationAHRI reference: 215936355 | 21.50 | 8.50 | 28200 | 2.06 | EPA 3725385 → |
CVAMA6021XMA*+UI+ furnace: 88*TB60070C21***Cold climate designationAHRI reference: 215935195 | 21.50 | 8.50 | 28600 | 2.04 | EPA 3725685 → |
CVAMA6021XMA*+UI+ furnace: 935CB48060C17***Cold climate designationAHRI reference: 215935235 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3725732 → |
CVAMA6021XMA*+UI+ furnace: 935CB60080C21***Cold climate designationAHRI reference: 215935245 | 21.50 | 8.50 | 28600 | 2.04 | EPA 3725912 → |
CVAVA3817XMA*+UI+ furnace: 986TD42080C17***Cold climate designationAHRI reference: 215935905 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3725939 → |
CVAMA6021XMA*+UI+ furnace: 987MC42080C17***Cold climate designationAHRI reference: 215935275 | 21.50 | 8.50 | 29000 | 2.02 | EPA 3725982 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →